Rockwell Automation Publication 2711T-QS002C-EN-P - March 2019

43

Second Generation MobileView Tethered Operator Terminal

4.

If desired, you can disconnect the tethered cable from the MobileView IP65 junction 
box.

MobileView Mounting Brackets

There are two mounting brackets available for second generation MobileView terminals. Both 
mounting brackets are an accessory, which means they must be ordered separately from the 
second generation MobileView 2711T terminal.

The MobileView standard mounting bracket (Cat. No. 2711T-BRACKET) is used for 
stationary operation or storage of the terminal. The MobileView VESA® mounting bracket (Cat. 
No. 2711T-VMBRACKET) connects to the back of the MobileView terminal, so the terminal 
can be mounted, stored, and locked into the bracket. This bracket is when locked storage is 
preferred. 

Each mounting bracket ships with a cutout template for installation

2711T-DS001

 with the 

standard mounting bracket and 

2711T-DS003

 for the VESA mounting bracket.

Figure 7 - MobileView Terminal Mounting Brackets

IMPORTANT

Do not disconnect the tethered cable from the MobileView IP65 junction box until you first 
shut down the second generation MobileView 2711T terminal.

See publication 

2711T-UM001

, MobileView 2711T Tethered Operator Terminal User Manual, 

for more information on the various ways to shut down and power off the terminal.

All dimensions are in mm (in.)

200 (7.9)

161 (6.3)

171 (6.7)

118 (4.6)

365 (14.4)

393 (15.5)

453 (17.8)

VESA Mounting Bracket

(cat. no. 2711T-VMBRACKET)

Standard Mounting Bracket

(cat. no. 2711T-BRACKET)

365 (14.4)

118 (4.6)

200 (7.9)

393 (15.5)

453 (17.8)

161 (6.3)

171 (6.7)

All dimensions are in mm (in.)

Summary of Contents for Allen-Bradley MobileView 2711T-B10I1N1

Page 1: ...Second Generation MobileView Tethered Operator Terminal Catalog Numbers 2711T B10I1N1 2711T T10I1N1 TC Quick Start OriginalInstructions...

Page 2: ...he Second Generation MobileView 2711TTerminal 7 The MobileView IP65 Junction Box 12 Initial Power Up of the Second Generation MobileView 2711TTerminal 29 Shut Down the Second Generation MobileView 271...

Page 3: ...circuit N C contacts 24V DC 500 mA max 4 Backside membrane keypad with tactile feedback 1 1 The 2711T T10I1N1 TC MobileView terminal does not have this feature 5 USB port 6 Productnameplate 7 Handle...

Page 4: ...tingcondition When applying functional safety restrict access to qualified authorized personnel who are trained and experienced Verify that unauthorized persons are not allowed to adjust settings or m...

Page 5: ...cifications of power supply lines in the connection cable are Cross section 26 AWG 0 126 mm2 Material zinc coated copper strand Line resistance 136 km 219 mi EnablingSwitch On the second generation Mo...

Page 6: ...st meet the safety level that results from the risk assessment of the machine See Risk Assessment of Machinery on page 7 The E stop has two potential free normally closed contacts to connect external...

Page 7: ...tion MobileView 2711T terminal When the back cover is removed you have access to the area that contains all connectors except the USB port 1 Place the second generation MobileView 2711T terminal with...

Page 8: ...2711T terminal functionality locks up and you cannot restart from the terminal desktop screen IMPORTANT The second generation MobileView 2711T terminalis shipped with the cable connection port open fo...

Page 9: ...screw and remove the gray fitting from the connector cable mounting assembly 5 Unscrew the strain relief from the connector cable mounting assembly to allow the red cable to slide freely Back Cover Ca...

Page 10: ...able connection of the second generation MobileView 2711T terminal 10 Reinstall the strain relief to the connector cable mounting assembly 11 Tighten the strain relief and the connector cable mounting...

Page 11: ...cuit 2 4 22 white green E stop circuit 2 5 6 gray E stop circuit 1 6 19 red blue E stop circuit 1 7 18 green brown Enabling switch circuit 1 8 20 yellow Enabling switch circuit 1 9 8 green Enabling sw...

Page 12: ...d Operator Terminal IP65 Junction Box Mounting Template publication 2711T DS004 Use this mounting template or the back plate of the IP65 junction box to drill the mounting holes Description Page Mount...

Page 13: ...ord grips on the 2711T JBIP65DC1 junction box The cover plate is fitted with a seal To maintain a tight seal and the IP65 rating when installed on an IP65 rated control cabinet install the cover plate...

Page 14: ...2711T JBIP65DC1 and 2711T JBIP65DM1 2 Use the back plate or the supplied cutout template to mark where to drill the four mounting holes for the junction box 3 With a drill and drill bit drill the four...

Page 15: ...back plate no screws are needed Wirethe2711T JBIP65DC1JunctionBox To wire the 2711T JBIP65DC1 junction box perform the following steps 1 See Figure 5 on page 16 to determine the appropriate cable outl...

Page 16: ...let 7 See page 17 for where to attach each wire to the appropriate terminal 8 After all wires are attached hand tighten the cable glands to secure the wires IMPORTANT To maintain the protection class...

Page 17: ...lity on page 20 You want to adjust the brightness of the illuminated E stop button on a second generation MobileView terminal You can press an adjustment button for four possible brightness levels see...

Page 18: ...e as follows ATTENTION Under high noise situations the Ethernet network can have packet loss of 10 at 100 Mbps By design Ethernet communication resends packets so there is no data loss but there is a...

Page 19: ...tionality Activate this DIP switch if the MobileView terminal has an illuminated E stop button For more details see DIP Switch on page 20 2 BOX ID Two address switches to set the address when Box ID f...

Page 20: ...ryTalk View ME software access the Rockwell Automation Knowledgebase link at https rockwellautomation custhelp com and search for AID 1043633 If Then The MobileView terminal to be used has no Box ID f...

Page 21: ...ct the M12 On Machine connections BoxIDFunctionality See Figure 6 on page 19 for where to find the Box ID address switches on the junction box circuit board See page 20 for how to configure Box ID fun...

Page 22: ...Box on page 15 remove the junction box from the screw bosses 2 Align the IP65 junction box with its mounted back plate 3 Mount the junction box to its back plate with the six supplied screws Torque t...

Page 23: ...iptions Pin No M12DryContact Pin Descriptions Pin No M12 E stop Pin Descriptions Pin No M12 Enabling Device Pin Descriptions 1 External 24V input 1 E stop 2 test output 1 Enabling device 2 test output...

Page 24: ...e illuminated E stop push button on the second generation MobileView terminal to trigger a stop Verify that the status indicator bar on the front of the IP65 junction box is lit and solid red in color...

Page 25: ...ANT Only perform step c if you are commissioning the unit performing maintenance or testing safety equipment because step c triggers a system emergency stop WARNING An IP65 junction box does not prote...

Page 26: ...2 pinbridgeconnectorisconnectedtothe junction box Solid yellow Begins the disconnect count time of 10 seconds after a second generation MobileView terminal or 22 pin bridge connector is disconnected f...

Page 27: ...activated Therefore the E stop push button on the MobileView terminal must be activated and then unlocked to reset the IP65 junction box If Then The connected second generation MobileView terminal has...

Page 28: ...tor includes a tethered cable so it can be secured with one of the bottom screws of an IP65 junction box For more information on the bottom screws see Mount the IP65 Junction Box to Its Back Plate on...

Page 29: ...ytheConnection To verify that the second generation MobileView 2711T terminal is properly connected perform the following steps 1 Attach the 22 pin MobileView connection cable to the IP65 junction box...

Page 30: ...leView connection cable to the IP65 junction box as shown on page 28 4 Test the E stop push button and the enabling switch to verify that each safety function is operating properly Verify that the mac...

Page 31: ...Windows End User Setup procedure To configure the Windows operating system on the second generation MobileView 2711T terminal perform the following steps 1 Enter the appropriate information to the sc...

Page 32: ...screen 4 After you add information press Next A license terms dialog box appears The license terms apply to Microsoft Windows Embedded Standard 7 operating system and all Allen Bradley software conte...

Page 33: ...3 Second Generation MobileViewTethered OperatorTerminal 6 Choose your appropriate date and time settings and press Next A pop up dialog box appears Windows is finalizing your settings When completed t...

Page 34: ...erminal Press to reboot restart the second generation MobileView 2711T terminal Press to toggle between open tasks and applications on the second generation MobileView 2711T terminal similar to Alt Ta...

Page 35: ...ager 3 The following screen appears Press OK If you change the EWF status then the second generation MobileView 2711T terminal automatically restarts 4 When the terminal desktop reappears the EWF stat...

Page 36: ...n the second generation MobileView 2711T terminal desktop press Network Settings The Local Area Connection icon appears with the network cable unplugged 2 Touch and hold for about 3 seconds and then r...

Page 37: ...dialog 9 Close Network Connections window to return to the second generation MobileView 2711T terminal desktop FTViewMEStation FactoryTalk View Machine Edition ME Station software on your second gener...

Page 38: ...uter as the source file A The destination storage type as External Storage 1 B This selection places the MER file on the SD card of your second generation MobileView terminal Select your second genera...

Page 39: ...nication configuration of the terminal with the communication configuration of the application 8 Depending on your application press Yes or No Wait while the application loads 9 Press Terminal Setting...

Page 40: ...ew terminal desktop to load and run the application Right clickTouchScreenFunctionalityandFactoryTalkViewMEStation If your FactoryTalk View ME Station uses momentary push buttons and you require long...

Page 41: ...2019 41 Second Generation MobileViewTethered OperatorTerminal 2 On the Touch tab of the Pen and Touch dialog box press Press and hold With Press and hold highlighted press Settings 3 Clear the Enable...

Page 42: ...nd generation MobileView 2711T terminal perform the following steps 1 Close FTView ME Station and return to the second generation MobileView terminal desktop 2 Press on the desktop taskbar to shut dow...

Page 43: ...nal can be mounted stored and locked into the bracket This bracket is when locked storage is preferred Each mounting bracket ships with a cutout template for installation 2711T DS001 with the standard...

Page 44: ...EN ISO 10218 1 2011 Robots and Robotic Devices Safety Requirements for Industrial Robots Part 1 Robots this standard applies only to the IP65 junction boxes The second generation MobileView 2711T term...

Page 45: ...ication 10 100 Ethernet Dimensions See page 3 Weight 1550 g 3 42 lb without options Electrical Attribute 2711T B10I1N1 2711T T10I1N1 TC Rated supply voltage 24V DC Supply voltage tolerance range 19 2...

Page 46: ...rent 5 6 A max Connector cycle duration 2 2 Applies to black 22 pin cable connector Test the connector monthly to verify that it locks properly Remove the IP65 junction box from operation after the co...

Page 47: ...connection cable 10 m 32 8 ft to connect the second generation terminal to the IP65 junction box 2711T 15MCABLE2 22 pin connection cable 15 m 49 2 ft to connect the second generation terminal to the...

Page 48: ...Association At theendofitslife thisequipmentshouldbe collectedseparatelyfromanyunsortedmunicipal waste PN 428428 PN 428428 AdditionalResources These documents contain more information about related pr...