7.5.1.2
“Deactivate drive group management” menu
This function is only available with the premium
version.
The Multilift I and Multilift Synchro cannot be used
with the premium version of the MultiControl II con-
trol unit.
The function allows you to adjust two defined drive
groups on a MultiControl II quadro individually,
synchronously or parallel to each other.
The function can be selected during initialization.
The drives of the first group are connected to drive slots M1 and
M2, the drives of the second group are connected to drive slots M3
.
In order to facilitate the function of the respective group, drive slots
M1 and M3 must be occupied at all times.
The following configurations are possible:
Total
Drive group 1
Drive group 2
M1
M1
-
M1 + M2
M1 + M2
-
M1 + M3
M1
M3
M1 + M2 + M3
M1 + M2
M3
M1 + M3 + M4
M1
M3 + M4
M1 + M2 + M3 + M4 M1 + M2
M3 + M4
Premium version
Drive group management
Operating the hand switch with 6 function buttons
Control menu > Commissioning menu
20.08.2021
Control unit RK MultiControl II duo/RK MultiControl II quadro
182