RIGOL
DS2000E User’s Guide
12-5
Internal Storage and Recall
Internal storage and recall support "Setups" in Storage. In the following part, the
storage and recall method and procedures are introduced.
1.
Save the specified oscilloscope setting in internal memory.
1)
Connect the signal to the oscilloscope and obtain stable display.
2)
Press Storage
Storage to select "Setups" and press Save to turn on the
disk management interface. Use
to select "Local Disk" (the characters
turn green) and press down
to open the local disk, as shown in Figure
3)
The local disk can store at most 10 setting files. Use
to select the
desired storage position, Save is illuminated and then press the softkey to
execute the saving operation. If the current position contains a file, the
original file can be overwritten or be deleted by pressing Delete. Use
to
select
and then press down
to return to the previous directory.
Figure 12-2 Local Disk (Save)
Note:
In internal storage, New File and New Folder are not available.