• [FCS]
[Heat Roller Temp: Clr/Sp], [Heat Roller Temp: White]
• [S]
[Heat Roller Temp: Clr/Sp], [Heat Roller Temp: White]
• [BW/FC/FCS: Fuser Setting HQ]
[Heat Roller Temp]
• [FCS: Fuser Setting HQ]
[Heat Roller Temp: Clr/Sp], [Heat Roller Temp: White]
• [S: Fuser Setting HQ]
[Heat Roller Temp: Clr/Sp], [Heat Roller Temp: White]
2.
Print 10 or more A4 sheets.
3.
Has the problem been resolved?
Yes
Go to the next step.
No
Repeat Step 1 to 3.
4.
Is the toner fusibility within the permissible range?
Yes
Finished!
No
Contact your service representative.
• After performing the solution, it is recommended to perform the color calibration of the external
controller.
• Check the toner fusibility as follows:
• The printed image does not come off.
• The toner does not come off even if it is lightly rubbed by a nail.
• The toner does not come off even if it is rubbed by the cloth for cleaning the contact glass.
If (J097) Appears
Cause:
This may occur if:
• Paper is skewed. For details see, page 91 "Paper Skew".
• Skew may be wrongly detected. For details see, page 91 "Wrong Detection of Skew".
Messages Reporting Paper Misfeeds