4.1 GENERAL CAUTIONS
4.1.1 NOTES ON THE MAIN POWER SWITCH
The main power button of this machine has been changed to a push-button switch (push button)
from the conventional rocker switch. The push switch has characteristics and specifications
different from the rocker switch. Care must be taken when replacing and adjusting parts.
Characteristics of the Push Switch (DC Switch)
Power is supplied to the machine even when the main power switch is turned OFF.
The push switch in this machine uses DC (direct current). Therefore, if the AC power cord is
connected to an electrical outlet, power is supplied to the controller board, the operation unit
and other modules even when the main power is turned OFF. When replacing the controller
board and the operation unit in this state, not only these boards, it will damage other electrical
components.
So, when performing maintenance work such as replacing parts, in addition to turning off the
main power with the push switch, always unplug the AC power cord.
When you disconnect the power cord from the AC wall outlet, inside the machine there is
still residual charge.
When you disconnect the power cord from the AC wall outlet, inside the machine for a while
there is still residual charge. Therefore, if you remove boards in this state, it can cause a
blown fuse or memory failure.
--How to remove the residual charge inside the machine--
After you unplug the power cord from the AC wall outlet, in order to remove the residual
charge from inside the machine, be sure to press the main power switch. Thus, the charge
remaining in the machine is released, and it is possible to remove boards.
When you reconnect the AC power cord into an AC wall outlet, the machine will start
automatically.
In order to remove the residual charge, push the main power switch while you disconnect the
AC power cord. At that time, the power ON flag inside the machine is set. Therefore, after you
finish work on the machine and reconnect the power cord to the AC, even if you do not press
the main power switch, the machine will start automatically and the moving parts will begin to
move. When working on moving parts, be careful that fingers or clothes do not get caught.
Summary of Contents for M160
Page 1: ...SERVICE MANUAL M160 M161 ...
Page 14: ......
Page 18: ......
Page 19: ...PRODUCT INFORMATION REVISION HISTORY Page Date Added Updated New None ...
Page 20: ......
Page 28: ......
Page 29: ...INSTALLATION REVISION HISTORY Page Date Added Updated New None ...
Page 30: ......
Page 115: ...PREVENTIVE MAINTENANCE REVISION HISTORY Page Date Added Updated New None ...
Page 116: ......
Page 122: ......
Page 123: ...REPLACEMENT AND ADJUSTMENT REVISION HISTORY Page Date Added Updated New None ...
Page 124: ......
Page 158: ...Fusing M160 M161 4 34 SM 4 Two brackets A 5 Fusing lamp A ...
Page 170: ...Paper Feed M160 M161 4 46 SM ...
Page 176: ...Paper Transport M160 M161 4 52 SM ...
Page 218: ......
Page 219: ...SYSTEM MAINTENANCE REVISION HISTORY Page Date Added Updated New None ...
Page 220: ......
Page 242: ......
Page 243: ...TROUBLESHOOTING REVISION HISTORY Page Date Added Updated New None ...
Page 244: ......
Page 366: ......
Page 367: ...ENERGY SAVE REVISION HISTORY Page Date Added Updated New None ...
Page 368: ......
Page 378: ...M160 M161 SERVICE MANUAL APPENDICES ...
Page 379: ......
Page 382: ...APPENDIX SPECIFICATIONS REVISION HISTORY Page Date Added Updated New None ...
Page 383: ......
Page 402: ...APPENDICES PREVENTIVE MAINTENANCE TABLES REVISION HISTORY Page Date Added Updated New None ...
Page 403: ......
Page 412: ...APPENDICES SP MODE TABLES REVISION HISTORY Page Date Added Updated New None ...
Page 413: ......
Page 647: ...M160 M161 FAX OPTION REVISION HISTORY Page Date Added Updated New None ...
Page 648: ......
Page 652: ......
Page 656: ......
Page 812: ...Fax Communication Features SM 156 M160 M161 Fax Option Report Sample ...
Page 821: ......
Page 823: ......