2. Going into Level 2 Mode from Level 1 Mode *
The flow chart on the next page shows in more detail how the machine goes
from Energy Saver Mode Level 1 to Level 2.
The machine will not go into Level 2 energy saver mode if one of the follow-
ing conditions exists.
•
Either a tx/rx/polling file is stored in the memory.
•
SAF memory not empty
•
Mechanical error(s)
•
NCU off-hook
•
Optional equipment installed (a printer interface, a G4 interface, or an
RS232C interface)
If there is a tx file in the memory
The machine stays in Energy Saver Mode Level 1 until it is time to send the
message. The machine then enters Level 0 while the message is sent. See
point 1 on the flow chart.
When the Energy Saver timer expires
When the energy saver timer expires after the machine entered Level 1 for
the first time (or, if a tx file was present, after the message was transmitted),
the machine will enter Level 2 if both of the following are met:
•
User Switch 05, bit 6 specifies Fusing Lamp Off
•
No condition #1 restrictions exist.
See point 2 on the flow chart.