Bypass Feed Slot
This machine does not detect paper width when the bypass feed slot is used.
The maximum feed length for bypass feed is 600 mm.
The mimimum feedable paper width is 191 mm.
Optional 100 Sheet Cassette
The paper size detector [A] is located
at the left hand side of the 100 sheet
cassette. The microswitches work in
the same way as in the standard cas-
sette.
When the 100 sheet cassette runs out
of paper, the paper end sensor actua-
tor [B] drops through a slot .
Paper Size/Paper End Detection
MFDU
EXIO-2
(IC4)
MFCE
LPC
SCP
(CPU)
Serial Interface
Bus Interface
Paper End Sensor
Standard Cassette
20-5
Paper Size Detector
Standard Cassette
25-4
25-6
25-3
Paper Size Detector 100
Sheet Cassette
7-1
7-2
7-4
Paper End Sensor
100 Sheet Cassette
7-1
Paper End
Paper End
1st Paper Feed Unit
2nd Paper Feed Unit
H515D515.wmf
[B]
[A]
H515D611.wmf
Detai
led De-
scr
ip
ti
ons
December 21st, 1995
DETAILED SECTION DESCRIPTIONS
PRINTING
2-31