5.12.2. Scanner Parameters
1. Contrast
Text Mode
Halftone Mode
Bit Switch
Initial Setting
Bit Switch
Initial Setting
Normal
Scanner 02
0E(H)
Scanner 05
09(H)
Lighten
Scanner 03
10(H)
Scanner 06
0D(H)
Darken
Scanner 04
0C(H)
Scanner 07
02(H)
Text Area
-
-
Scanner 08
08(H)
2. Margins
Parameter
Formula
RAM
Address
Unit
Initial
Setting
W1, W2
Not adjustable
L1
This parameter changes the number of tx
motor steps after the scan line sensor is
activated.
To increase the margin by x mm:
New setting = Current s 15.4x
To decrease the margin by x mm:
New setting = Current setting - 15.4x
Initial setting of L1: 2 mm
48061C(H)
1
15.4
mm
9A(H)
[154(D)]
L2
Not adjustable (Original length - L1 - L3)
L3
This parameter changes the number of tx
motor steps after the scan line sensor is
deactivated.
To increase the margin by x mm:
New setting = Current setting - 15.4x
To decrease the margin by x mm:
New setting = Current s 15.4x
Initial setting of L3: 2 mm
480620(H)
(standard)
480622(H)
(detail)
480624(H)
(fine)
1
15.4
mm
79(H)
[121(D)]
93(H)
[147(D)
AF(H)
[175(D)]
H515R651.wmf
Replacem
ent
Adj
u
s
December 21st, 1995
REPLACEMENT AND ADJUSTMENT
IMAGE ADJUSTMENT
5-41