2. Margins (Sub Scan Direction)
Parameter
Formula
RAM
Address
Unit
Initial
Setting
L1
Standard and 100 sheet cassette:
To increase the margin by x mm:
New setting = Current s x/0.68
To decrease the margin by x mm:
New setting = Current setting - x/0.68
Initial setting of L1: 2 mm
Other:
To increase the margin by x mm:
New setting = Current s x/0.34
To decrease the margin by x mm:
New setting = Current setting - x/0.34
Initial setting of L1: 2 mm
Standard
cassette:
4804EA(H)
1st paper
feed unit:
4804EB(H)
2nd paper
feed unit:
4804EC(H)
100 sheet
cassette:
4804EF(H)
Bypass
feeder:
4804F0(H)
0.68
mm
0.34
mm
0.34
mm
0.68
mm
0.34
mm
00(H)
0D(H)
0D(H)
05(H)
00(H)
L2
Not adjustable
L3
This is only adjustable in bypass feed mode.
To increase the margin by x mm:
New setting = Current setting - x/0.34
To decrease the margin by x mm:
New setting = Current s x/0.34
Example: To increase the margin by 5 mm.
5/0.34
≈
14.7
≈
15(D) = F(H)
New setting = 3B - F = 2C(H)
480586(H)
0.34
mm
4A(H)
H515R651.wmf
Replacem
ent
Adj
u
s
December 21st, 1995
REPLACEMENT AND ADJUSTMENT
IMAGE ADJUSTMENT
5-43