3. When replacing the MFDU or other components
When the MFCE must be removed to access or remove other components in-
side the machine, follow the procedure below.
1. Make sure that System Switch 16 - bit 0 is set to 1, and that the battery
switch on the IC card is at the ON position.
2. Turn off the machine, remove the IC card, and replace the required com-
ponents inside the machine.
3. After replacement has been completed, put back the MFCE and the IC
card as they originally were, then turn on the machine.
I
CAUTION
If the machine is turned on without the card being put back in the
lower IC card slot, the machine recognizes that the card has been
removed and all the data programmed in the card will not be
accessable any more.
4. Make sure that all the programmed data in the IC cards can still be used.