287
7
Chapter 7 Error Display
Code display Detection timing
Cause
Page
E012
Error : Clamp motor locked
The clamp motor is defective.
The clamp sensor 1 is defective.
The clamp sensor 2 is defective.
The drive PCB unit is defective.
The main PCB unit is defective.
The 24V power supply is defective.
Disconnection/Poor connector
connection
Within 3 seconds after the clamp motor starts rotating,
the clamp sensor 1/the clamp sensor 2 does not detect
that B mode/C mode is entered.
E013
Error : Scanner stepping motor locked
The scanner stepping motor is
defective.
The slider position sensor 1 is defective.
The slider position sensor 2 is defective.
Poor connector connection
The drive PCB unit is defective.
The main PCB unit is defective.
The 24V power supply is defective.
Disconnection/Poor connector
connection
When moving the slider from end to end, the slider position
sensor 1/the slider position sensor 2 does not detect that
the slider reaches the desired position within 6 seconds
after the scanner stepping motor starts rotating.
When moving the slider from the position other than the
end to the end, the slider position sensor 1/the slider
position sensor 2 does not detect that the slider reaches
the desired position within 12 seconds after the scanner
stepping motor starts rotating.
E015
Error : Vertical registration motor locked
The vertical registration motor is defective.
The vertical registration encoder sensor is
defective.
The vertical registration center sensor is
defective.
The drive PCB unit is defective.
The main PCB unit is defective.
The 24V power supply is defective.
Disconnection/Poor connector connection
The vertical registration encoder sensor does not detect the
edge within 0.5 seconds after the vertical registration motor
starts rotating.
Although the vertical registration motor is rotating, the vertical
registration encoder sensor does not detect the edge for 0.3
seconds.
Although the vertical registration section is moved by 1.25 x
of the maximum one-side vertical registration moving distance
back to the center, the vertical registration center sensor does
not detect that the vertical registration reaches the center.
E017
Error : ADF stepping motor locked
The main PCB unit is defective.
Write/readout to FPGA stepping controller of the
main PCB is defective.
E018
Error : FPGA
The main PCB unit is defective.
-
Write/readout to FPGA of the main PCB is defective.
E020
Error : Tape dispenser cutter motor locked
The tape dispenser cutter motor is defective.
The tape dispenser cutter is defective.
The tape dispenser cutter home position
sensor is defective.
The tape dispenser PCB unit is defective.
The drive PCB unit is defective.
Disconnection/Poor connector connection
Tape cutting is defective.
E021
Error : Communication with the tape dispenser
is not performed normally
The tape dispenser PCB unit is
defective.
The main PCB unit is defective.
Disconnection/Poor connector
connection
Communication between the main PCB and the tape
dispenser PCB is defective.
2
Summary of Contents for DD 5450
Page 1: ...RICOH DD5450 DD5440 Machine Code C284 C283 Field Service Manual June 2016...
Page 2: ......
Page 15: ...Chapter 1 Dimensions 13 2 Dimensions 2 622 1405 555 228 1080 710 980 688 370 Unit mm...
Page 37: ...35 Chapter 2 Machine Installation 5 Touch OK DATE TIME is set 6 Touch END 1...
Page 170: ......
Page 262: ......