190
4
Chapter 4 Scanner Section
● Required items
Two Slider A installation jigs
Four Set screws
1. Move the slider A by rotating the timing
pulley to align the frame holes with the slider A
positioning holes. (See the figure on the right.)
● Do not move Slider A with hand.
2. Install the two slider A installation jigs with the
four screws.
3. Secure the wire with the two screws.
4. Remove the four screws to remove the two slider A
installation jigs.
5. Install the LED lamp with the two screws.
(Pan head screw with spring plain washer 3 x 6)
Reinstallation
Install the slider B first and then slider A.
Insert the jig to
secure the wire.
Slider A installation jig
Slider A installation jig
Screw
Slider A
Screw
Screw
Jig
Jig
Align hole positions
2
IMPORTANT
Summary of Contents for DD 5450
Page 1: ...RICOH DD5450 DD5440 Machine Code C284 C283 Field Service Manual June 2016...
Page 2: ......
Page 15: ...Chapter 1 Dimensions 13 2 Dimensions 2 622 1405 555 228 1080 710 980 688 370 Unit mm...
Page 37: ...35 Chapter 2 Machine Installation 5 Touch OK DATE TIME is set 6 Touch END 1...
Page 170: ......