Chapter 4 Master Making/Master Feed and Ejection Section
(1) Removing the Master Ejection Box
<< Master Ejection Section >>
1. Push the lever and open the master ejection
box.
(2) Removing the Eject Motor (Roll-Up Motor)
1. Remove the screw to remove the cover.
(S tight hexagon head WH rounded end screw
3 x 6)
2. Loosen the screw and loosen the tension of
the timing belt.
(Pan head screw with spring plain washer 4 x 8)
3. Remove the timing belt from the pulley.
4. Loosen the screw to remove the motor pulley.
(Hexagon socket set screw cup point 4 x 6)
5. Disconnect the connector.
6. Remove the three screws to remove the motor.
(Pan head screw with spring plain washer 3 x 6)
● Be sure to adjust the tension after installing
the motor.
Reinstallation
Screw
Screws
Screws
Pulley
Cover
Timing belt
Eject motor
Screw
Screw
Screw
Connector
3. Remove the two screws and disconnect the
connector, then pull the master ejection box
upward to remove it.
(Hexagon upset head screw with spring plain
washer 5 x 10)
2. Open the lock-type cable clamp.
Cord clamp
3
IMPORTANT
Non-operator's side