No. Result
Description
Possible Causes/Action
53
ID sensor
coefficient (K5)
detection error
Not enough data can be
sampled.
• Solid image is not sufficient density:
1. Retry the process control.
2. Replace the ID sensors.
3. Replace the IOB board.
• Solid image is O.K.
1. Replace the ID sensors.
2. Replace the IOB board.
• ID sensor is dirty:
1. Clean the ID sensors.
2. Retry the process control.
54
ID sensor
coefficient (K5)
maximum/
minimum error
When the K5 is more than
the value of
SP3-362-003 or less
than the value of
SP3-362-004, the error
54 is displayed.
• ID sensor pattern density is too high or low.
• ID sensor or shutter is defective.
Same as 53
55
Gamma error:
Maximum
Gamma is out of range.
5.0 < Gamma
• ID sensor pattern density is too high.
• Hardware defective.
Same as 53
56
Gamma error:
Minimum
Gamma is out of range.
Gamma < 0.15
• ID sensor pattern density is too low.
• Hardware defective.
1. Same as 53
2. Replace the toner supply pump unit.
57
Vk error:
Maximum
Vk is out of range.
150 < Vk
• ID sensor pattern density is too low.
• Hardware defective.
Same as 53
58
Vk error:
Minimum
Vk is out of range.
Vk < –150
• ID sensor pattern density is too high.
• Background dirty
• Hardware defective
Same as 53
Process Control Error Conditions
103
4
Summary of Contents for AP-P2 G188
Page 1: ...Model AP P2 Machine Code G188 G189 Field Service Manual January 2009 Subject to change ...
Page 2: ......
Page 12: ...Electrical Component Defects 253 INDEX 255 10 ...
Page 22: ...1 Product Information 20 1 ...
Page 43: ...Item SP No Function Default Printer Installation 41 2 ...
Page 100: ...3 Preventive Maintenance 98 3 ...
Page 111: ...Left Cover 1 Left cover A x 6 Rear Cover 1 Rear cover A x 6 Exterior Covers 109 4 ...
Page 116: ...2 Filter B 3 Ozone filter C 4 Replacement and Adjustment 114 4 ...
Page 174: ...6 Development clutch K A x 1 4 Replacement and Adjustment 172 4 ...
Page 243: ...Controller Self Diagnostics 241 5 ...
Page 250: ...5 System Maintenance Reference 248 5 ...
Page 256: ...6 Troubleshooting 254 6 ...
Page 257: ...Model AP P2 Machine Code G188 G189 Appendices January 2009 Subject to change ...
Page 258: ......
Page 282: ...1 Appendix Specifications 24 1 ...
Page 286: ...2 Appendix Preventive Maintenance Tables 28 2 ...
Page 358: ...3 Appendix Service Call Conditions 100 3 ...
Page 374: ...5 Appendix Troubleshooting Guide 116 5 ...
Page 383: ...Sensor Locations Jam Detection 125 6 ...
Page 384: ...6 Appendix Jam Detection 126 6 ...
Page 392: ...7 Appendix Electrical Component Defects 134 7 ...