No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
687
D
Memory address command error
The BCU does not receive a memory address command from the controller 120
seconds after paper is in the position for registration.
• Loose connection
• Defective controller
• Defective BCU
1. Check if the controller is firmly connected to the BCU.
2. Replace the controller.
3. Replace the BCU.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
690
D
GAVD communication error
• The I2C bus device ID is not identified during initialization.
• A device-status error occurs during I2C bus communication.
• The I2C bus communication is not established due to an error other than a
buffer shortage.
• Loose connection
• Defective BCU
• Defective LD controller board
1. Turn the main switch off and on.
2. Check the cable connection.
3. Replace the laser optics-housing unit.
4. Replace the BCU.
3. Appendix: Service Call Conditions
70
3
Summary of Contents for AP-P2 G188
Page 1: ...Model AP P2 Machine Code G188 G189 Field Service Manual January 2009 Subject to change ...
Page 2: ......
Page 12: ...Electrical Component Defects 253 INDEX 255 10 ...
Page 22: ...1 Product Information 20 1 ...
Page 43: ...Item SP No Function Default Printer Installation 41 2 ...
Page 100: ...3 Preventive Maintenance 98 3 ...
Page 111: ...Left Cover 1 Left cover A x 6 Rear Cover 1 Rear cover A x 6 Exterior Covers 109 4 ...
Page 116: ...2 Filter B 3 Ozone filter C 4 Replacement and Adjustment 114 4 ...
Page 174: ...6 Development clutch K A x 1 4 Replacement and Adjustment 172 4 ...
Page 243: ...Controller Self Diagnostics 241 5 ...
Page 250: ...5 System Maintenance Reference 248 5 ...
Page 256: ...6 Troubleshooting 254 6 ...
Page 257: ...Model AP P2 Machine Code G188 G189 Appendices January 2009 Subject to change ...
Page 258: ......
Page 282: ...1 Appendix Specifications 24 1 ...
Page 286: ...2 Appendix Preventive Maintenance Tables 28 2 ...
Page 358: ...3 Appendix Service Call Conditions 100 3 ...
Page 374: ...5 Appendix Troubleshooting Guide 116 5 ...
Page 383: ...Sensor Locations Jam Detection 125 6 ...
Page 384: ...6 Appendix Jam Detection 126 6 ...
Page 392: ...7 Appendix Electrical Component Defects 134 7 ...