Color Mode [Color]
[K]: Black in B&W mode
[Y], [M], or [C]: Yellow, Magenta, or Cyan in Full Color mode
[YMC]: Only for Yellow, Magenta, and Cyan
[FC]: Full Color mode
[FC, K], [FC, Y], [FC, M], or [FC, C]: Black, Yellow, Magenta, or Cyan in full color mode
Print Mode
S: Simplex
D: Duplex
Process Speed
L: Low speed (77 mm/s)
M: Middle speed (154 mm/s)
H: High speed (P2d: 230, P2c 205 mm/s)
Others
The following symbols are used in the SP mode tables.
FA: Factory setting
(Data may be adjusted from the default setting at the factory. Refer to the factory setting sheets enclosed.
You can find it under the jammed paper removal decal.)
DFU: Design/Factory Use only
Do not touch these SP modes in the field.
A sharp (#) to the right hand side of the mode number column means that the main switch must be turned
off and on to effect the setting change.
An asterisk (*) to the right hand side of the mode number column means that this mode is stored in the
NVRAM. If you do a RAM clear, this SP mode will be reset to the default value. “ENG” and “CTL” show
which NVRAM contains the data.
• ENG: NVRAM on the BCU board
• CTL: NVRAM on the controller board
• NV: NVRAM on the NVRAM expansion board (user account enhancement kit)
The settings of each SP mode are explained in the right-hand column of the SP table in the following way.
[Adjustable range / Default setting / Step ] Alphanumeric
• If “Alphanumeric” is written to the right of the bracket as shown above, the setting of the SP mode
shows on the screen using alphanumeric characters instead of only numbers. However, the settings
in the bracket in the SP mode table are explained by using only the numbers.
SSP: This denotes a “Special Service Program” mode setting.
Service Program Mode
233
5
Summary of Contents for AP-P2 G188
Page 1: ...Model AP P2 Machine Code G188 G189 Field Service Manual January 2009 Subject to change ...
Page 2: ......
Page 12: ...Electrical Component Defects 253 INDEX 255 10 ...
Page 22: ...1 Product Information 20 1 ...
Page 43: ...Item SP No Function Default Printer Installation 41 2 ...
Page 100: ...3 Preventive Maintenance 98 3 ...
Page 111: ...Left Cover 1 Left cover A x 6 Rear Cover 1 Rear cover A x 6 Exterior Covers 109 4 ...
Page 116: ...2 Filter B 3 Ozone filter C 4 Replacement and Adjustment 114 4 ...
Page 174: ...6 Development clutch K A x 1 4 Replacement and Adjustment 172 4 ...
Page 243: ...Controller Self Diagnostics 241 5 ...
Page 250: ...5 System Maintenance Reference 248 5 ...
Page 256: ...6 Troubleshooting 254 6 ...
Page 257: ...Model AP P2 Machine Code G188 G189 Appendices January 2009 Subject to change ...
Page 258: ......
Page 282: ...1 Appendix Specifications 24 1 ...
Page 286: ...2 Appendix Preventive Maintenance Tables 28 2 ...
Page 358: ...3 Appendix Service Call Conditions 100 3 ...
Page 374: ...5 Appendix Troubleshooting Guide 116 5 ...
Page 383: ...Sensor Locations Jam Detection 125 6 ...
Page 384: ...6 Appendix Jam Detection 126 6 ...
Page 392: ...7 Appendix Electrical Component Defects 134 7 ...