7.3 HOT ROLLER REPLACEMENT
1. Remove the exit unit. (See Exit Unit Removal.)
2. Remove the fusing unit. (See Fusing Unit Removal.)
3. Remove the fusing cover [A] (1 screw).
4. Remove the thermoswitch bracket [B] (1 screw).
5. Disconnect the connector [C] of the fusing lamp from the thermoswitch
[D].
6. Remove the thermistor [E] (1 screw).
7. Remove the front [F] and rear [G] support brackets of the fusing lamp
(1 screw each).
8. Pull the fusing lamp [H] out of the front end of the hot roller.
[H]
[A]
[G]
[E]
[B]
[C]
[F]
[D]
A151/A152
5-66
FSM
Summary of Contents for A151
Page 1: ...SERVICE MANUAL PN RCFM3213 A151 A152 A202 A203 RICOH GROUP COMPANIES ...
Page 2: ...SERVICE MANUAL A151 A152 A202 A203 RICOH GROUP COMPANIES ...
Page 3: ...A151 A152 A202 A203 FIELD SERVICE MANUAL PN RCFM3213 ...
Page 4: ......
Page 6: ......
Page 8: ......
Page 10: ......
Page 22: ......
Page 26: ......
Page 27: ...OVERALL MACHINE INFORMATION ...
Page 28: ......
Page 32: ......
Page 33: ...GUIDE TO COMPONENTS ...
Page 34: ......
Page 42: ......
Page 43: ...INSTALLATION ...
Page 44: ......
Page 55: ...SERVICE TABLES ...
Page 56: ......
Page 95: ...REPLACEMENT AND ADJUSTMENT ...
Page 96: ......
Page 193: ...TROUBLESHOOTING ...
Page 194: ......
Page 250: ......
Page 251: ...DOCUMENT FEEDER A296 ...
Page 252: ......
Page 268: ......
Page 274: ......
Page 277: ...A202 A203 SERVICE MANUAL ...
Page 278: ......
Page 337: ...DOCUMENT FEEDER A662 ...
Page 338: ......
Page 359: ...TECHNICAL SERVICE BULLETINS ...
Page 360: ......
Page 372: ...Tech Service Bulletin No 3013 3213 008 Page 2 of 3 Continued ...
Page 373: ...Tech Service Bulletin No 3013 3213 008 Page 3 of 3 ...