10. DEVELOPMENT
10.1 DEVELOPMENT BIAS CIRCUIT
The main board su24 volts to the CC/Grid/Bias power pack at CN1-1.
When the
key is pressed, the CPU starts sending the bias trigger pulses
to CN1-4. This energizes the development bias circuit within the
CC/Grid/Bias power pack, which applies a high negative voltage to the
development roller. The development bias is applied whenever the drum is
rotating.
The bias trigger pulse applied to CN1-4 is a pulse width modulated signal
(PWM signal). The width of the pulses controls the voltage level of the
development roller. As the width of the trigger pulses increase, the voltage to
the development roller also increases. The power pack is equipped with its
own feedback circuit to monitor the development bias voltage.
Bias Trig (PWM) [
▲
0
→
0/5]
Power Pack -
CC/Grid/Bias
(P1)
Charge Corona
Grid
Development
Bias
A203D505.wmf
A203D506.wmf
DEVELOPMENT
A202/A203
8-16
SM
Summary of Contents for A151
Page 1: ...SERVICE MANUAL PN RCFM3213 A151 A152 A202 A203 RICOH GROUP COMPANIES ...
Page 2: ...SERVICE MANUAL A151 A152 A202 A203 RICOH GROUP COMPANIES ...
Page 3: ...A151 A152 A202 A203 FIELD SERVICE MANUAL PN RCFM3213 ...
Page 4: ......
Page 6: ......
Page 8: ......
Page 10: ......
Page 22: ......
Page 26: ......
Page 27: ...OVERALL MACHINE INFORMATION ...
Page 28: ......
Page 32: ......
Page 33: ...GUIDE TO COMPONENTS ...
Page 34: ......
Page 42: ......
Page 43: ...INSTALLATION ...
Page 44: ......
Page 55: ...SERVICE TABLES ...
Page 56: ......
Page 95: ...REPLACEMENT AND ADJUSTMENT ...
Page 96: ......
Page 193: ...TROUBLESHOOTING ...
Page 194: ......
Page 250: ......
Page 251: ...DOCUMENT FEEDER A296 ...
Page 252: ......
Page 268: ......
Page 274: ......
Page 277: ...A202 A203 SERVICE MANUAL ...
Page 278: ......
Page 337: ...DOCUMENT FEEDER A662 ...
Page 338: ......
Page 359: ...TECHNICAL SERVICE BULLETINS ...
Page 360: ......
Page 372: ...Tech Service Bulletin No 3013 3213 008 Page 2 of 3 Continued ...
Page 373: ...Tech Service Bulletin No 3013 3213 008 Page 3 of 3 ...