5.2 EXPLANATION OF REGULAR PM
Item
Explanation
Optics Unit
Mirrors, Lens,
Reflector, Exposure
Glass, Platen Cover
Stains on any part of the optics unit result in a dirty
background, black lines, black spots, or areas of
decreased sharpness on the copy image. Periodic
cleaning is required. The exposure glass and the
platen cover must also be cleaned. If stains on the
platen cover cannot be removed, it must be replaced.
Exposure Lamp
Deterioration of the exposure lamp affects the copy
image. Inspect the lamp at regular intervals and
replace if discolored.
Paper Feed,
and
Registration
Feed Roller
If paper powder or dust adheres to the feed rollers
and/or rollers are worn out, paper may not feed
correctly and/or skewing may result. Cleaning or
replacement is required at regular intervals.
Registration Roller
A dirty registration roller can cause paper to register
incorrectly, skew, or misfeed. Cleaning is required at
regular intervals.
Transport
Transfer Guide Plate If the transfer guide plate is dirty, the back side of
copies may become dirty. Clean the plate at regular
intervals.
Around
Drum
Charge Wires
Dirty charge wires may cause uneven image density.
They should be cleaned or replaced at regular
intervals.
End Blocks
Toner tends to accumulate on the corona end blocks,
and this can result in poor copy quality or even a high
voltage leak. Clean end blocks at regular intervals.
QL
If toner accumulates on the QL, a dirty background or
a repeating negative image may result.
Clean the QL at regular intervals.
ID Sensor
If paper dust or toner accumulates on the ID sensor,
the toner density cannot be controlled correctly. This
results in light copy or overtorning. Clean this sensor
at regular intervals.
Erase Lamp
If toner accumulates on the erase lamp, a dirty
background may occur that becomes progressively
worse in long copy runs. Clean this lamp at regular
intervals.
Cleaning
Unit
Cleaning Blade
A dirty or worn out cleaning blade will cause black
lines on copies and/or scratches on the drum. The
blade must be replaced or cleaned at regular
intervals.
To avoid damaging the drum, dust with setting
powder evenly along the edge and surface of the
blade after replacement or cleaning.
Used Toner Tank
If the used toner tank becomes full, "E70" lights and
copying becomes inhibited. To prevent unnecessary
EM calls, the used toner tank should be emptied at
every visit.
A151/A152
4-32
FSM
Summary of Contents for A151
Page 1: ...SERVICE MANUAL PN RCFM3213 A151 A152 A202 A203 RICOH GROUP COMPANIES ...
Page 2: ...SERVICE MANUAL A151 A152 A202 A203 RICOH GROUP COMPANIES ...
Page 3: ...A151 A152 A202 A203 FIELD SERVICE MANUAL PN RCFM3213 ...
Page 4: ......
Page 6: ......
Page 8: ......
Page 10: ......
Page 22: ......
Page 26: ......
Page 27: ...OVERALL MACHINE INFORMATION ...
Page 28: ......
Page 32: ......
Page 33: ...GUIDE TO COMPONENTS ...
Page 34: ......
Page 42: ......
Page 43: ...INSTALLATION ...
Page 44: ......
Page 55: ...SERVICE TABLES ...
Page 56: ......
Page 95: ...REPLACEMENT AND ADJUSTMENT ...
Page 96: ......
Page 193: ...TROUBLESHOOTING ...
Page 194: ......
Page 250: ......
Page 251: ...DOCUMENT FEEDER A296 ...
Page 252: ......
Page 268: ......
Page 274: ......
Page 277: ...A202 A203 SERVICE MANUAL ...
Page 278: ......
Page 337: ...DOCUMENT FEEDER A662 ...
Page 338: ......
Page 359: ...TECHNICAL SERVICE BULLETINS ...
Page 360: ......
Page 372: ...Tech Service Bulletin No 3013 3213 008 Page 2 of 3 Continued ...
Page 373: ...Tech Service Bulletin No 3013 3213 008 Page 3 of 3 ...