2.5 SERVICE CALL AND USER CODE TABLE
Service Call Code
E-code
Contents
SP Mode No.
(SC Counter)
11
Exposure Lamp Error
The feed back signal becomes higher than 4.2 volts (rms)
for 1.0 second when the exposure lamp is on, or it
becomes higher than 1.0 volt (rms) for 1.0 second when
the exposure lamp is off.
SP122
(Exposure Lamp)
12
Exposure Lamp Error
The feed back signal falls below 0.5 volt (rms) for
1.0 second when the exposure lamp is on, or the
exposure lamp stays on for longer than 10 seconds.
13
Zero Cross Signal Error
The CPU does not receive the zero cross signal within 2.0
seconds.
–
21
Scanner Home Position Error
The scanner home position sensor’s output remains LOW
(de-actuated) for 9 seconds after the main switch is turned
on.
SP121 (Optics)
22
Scanner Home Position Error
The scanner home position sensor’s output remains HIGH
(actuated) for 1.0 second after the scanner starts.
28
Lens Home Position Error (FT3213 copier only)
The lens home position sensor’s output remains LOW
(de-actuated) for 6.0 seconds after the lens moves to the
home position.
29
Lens Home Position Error (FT3213 copier only)
The lens home position sensor’s output remains HIGH
(actuated) for 4.0 seconds after the lens leaves the home
position.
2A
4th/5th Mirror Home Position Error
(FT3213 copier only)
The 4th/5th mirror home position sensor’s output remains
LOW (de-actuated) for 3.0 seconds after the 4th/5th mirror
assembly moves to the home position.
2B
4th/5th Mirror Home Position Error
(FT3213 copier only)
The 4th/5th mirror home position sensor’s output remains
HIGH (actuated) for 4.0 seconds after the 4th/5th mirror
assembly leaves the home position.
40
Optics Thermistor Error
The optics thermistor is defective (open).
52
Fusing Warm-up Error
The temperature detected by the thermistor does not
reach 150°C within 45 seconds after the main switch is
turned on.
SP124
(Fusing)
Refer to NOTE.
53
Fusing Overheat
The temperature detected by the thermistor becomes
higher than 240°C.
55
Fusing Thermistor Open
The temperature detected by the thermistor does not
reach 2°C within 20 seconds after the main switch is
turned on.
SER
V
IC
E
T
ABL
E
S
FSM
4-23
A151/A152
Summary of Contents for A151
Page 1: ...SERVICE MANUAL PN RCFM3213 A151 A152 A202 A203 RICOH GROUP COMPANIES ...
Page 2: ...SERVICE MANUAL A151 A152 A202 A203 RICOH GROUP COMPANIES ...
Page 3: ...A151 A152 A202 A203 FIELD SERVICE MANUAL PN RCFM3213 ...
Page 4: ......
Page 6: ......
Page 8: ......
Page 10: ......
Page 22: ......
Page 26: ......
Page 27: ...OVERALL MACHINE INFORMATION ...
Page 28: ......
Page 32: ......
Page 33: ...GUIDE TO COMPONENTS ...
Page 34: ......
Page 42: ......
Page 43: ...INSTALLATION ...
Page 44: ......
Page 55: ...SERVICE TABLES ...
Page 56: ......
Page 95: ...REPLACEMENT AND ADJUSTMENT ...
Page 96: ......
Page 193: ...TROUBLESHOOTING ...
Page 194: ......
Page 250: ......
Page 251: ...DOCUMENT FEEDER A296 ...
Page 252: ......
Page 268: ......
Page 274: ......
Page 277: ...A202 A203 SERVICE MANUAL ...
Page 278: ......
Page 337: ...DOCUMENT FEEDER A662 ...
Page 338: ......
Page 359: ...TECHNICAL SERVICE BULLETINS ...
Page 360: ......
Page 372: ...Tech Service Bulletin No 3013 3213 008 Page 2 of 3 Continued ...
Page 373: ...Tech Service Bulletin No 3013 3213 008 Page 3 of 3 ...