![Rice Lake 181881 Technical Manual Download Page 22](http://html1.mh-extra.com/html/rice-lake/181881/181881_technical-manual_1454084022.webp)
Load Ranger Wheel Weigh Pad System
16
Visit our website
www.RiceLake.com
3.2.1 Setup Ai-1 and Pair Wheel Pads
NOTE:
The indicator channel must match wheel weigh pad(s) channel number(s) assigned in
Section 3.1.3 on page 13
.
1. Turn off all wheel weigh pads.
2. Press
to turn on the Ai-1 indicator.
3. Access the
Technical Setup
menu (
Section 4.2 on page 34
).
4. Press
to go to second
Setup menu
page.
5. In the second page, press
.
Serial Port
menu displays.
6. Press
.
Radio Frequency interface
displays.
7. Press
. The Channel keyboard displays.
8. Enter the required channel number.
NOTE: The default channel number is 27. The wheel weigh pad channel number must match the indicator channel number
it will pair with. The Ai-1 indicator supports channels 00 - 38. If using multiple groups of indicators and wheel weigh pads,
the channel numbers must be unique for each group.
Figure 3-6. Channel Keyboard
9. Press
. A
Channel
prompt displays.
Figure 3-7. Channel Success Prompt
10. Press
to close the prompt and return to the
Radio Frequency interface
menu.
11. Press
twice.
12. press
once.
13. Press
.
14. Press
.
Serial ports
F2
Radio frequency interface
F5
Radio frequency interface
F5
Channel
F2
Channel
1
Esc
2
/
3
4
5
*
6
7
BkSp
8
-
9
C
OK
0
+
0
~
38
27
OK
Configuration sent Successfully.
Channel
OK
OK
Calibration
F1
Scale selection
F1
1 scale/s