7.2.2.4 Monitoring
Settings
o
To start the “Monitoring” mode select the corresponding line on the “Scan” page and press
“OK” or the hotkey “Start Scan” (s. Figure 35, position 1).
Figure 35. "Monitoring" has been activated
o
Pressing the hotkey “Stop Scan” (s. Figure 35, position 2) will terminate the current scan mode
and change to the bearing of the frequency that was set before the scan mode has been
activated.
o
You can also stop the scan mode by pressing the “HOME” button on the “Bearing” page with
activated scan. After you have confirmed the special dialog (s. Figure 36), this mode will be
terminated.
Figure 36. Confirming of leaving the scan mode
o
Pressing the hotkey “Go to Result” (s. Figure 28, position 3) during the monitoring is currently
running, will terminate the scan mode, adopt the frequency which was found in this scan last
time and change to the “Bearing” page.
o
Pressing the hotkey “Go to Result” if the scan mode is not activated, will lead to the “Bearing”
page adopting the last result as the bearing frequency.
This hotkey appears only if there is a result for this scan.
o
Pressing the hotkey “Edit Scan” (s. Figure 24, position 6) will open the dialog for changing the
monitoring settings (s. Figure 37).