RT-500-M
RHOTHETA
Page 130 of 168
User Manual
o
Press the hotkey “Set Default” to use the default value (“PTT”).
o
Confirm the setting with “OK” or leave the dialog without adopting the new value by pressing
“ESC”.
Output (Pin 10)
A signal can be allocated to the “programmable pin OUT” (s. chapter 8.1, POWER + IO).
There are four setting possibilities for this pin:
1. Alarm Out: Choosing this setting connects the programmable output pin with the pin for the alarm
relay (s. Figure 162, position 2).
2. Squelch Out: Choosing this setting (s. Figure 162, position 3) connects the programmable output
pin with the “Squelch Out” pin of the “POWER + IO” connector (s. chapter 8.1).
3. Status Out: Choosing this setting connects the programmable output pin with the internal error
status output of the device (s. Figure 162, position 4).
That means, if there are no errors, the output will be active (open collector). If there is an error, the
output will be not active (open collector).
4. No Function: Choosing this setting allocates the state “No Function” to the programmable pin,
which means that the pin is not related to any function (s. Figure 162, position 1).
o
To configure the programmable output pin, press the hotkey “Edit Value”, while the setting
“Input (Pin 2)” is marked.
Figure 162. Assigning a function to the output pin
o
Choose the new setting using one of the hotkeys (s. Figure 162), which will then appear in the
“New Setting” field.
o
Press the hotkey “Set Default” (s. Figure 162, position 5) to use the default value (“Alarm
Out”).
o
Confirm the setting with “OK” or leave the dialog without adopting the new value by pressing
“ESC”.