![RGB Spectrum Linx 1600 User Manual Download Page 66](http://html.mh-extra.com/html/rgb-spectrum/linx-1600/linx-1600_user-manual_1450537066.webp)
C O M M A N D S
EDID Commands
350-10035-01 v4.1.1
Linx DVI Matrix Switchers User’s Guide
54
6.5 EDID Commands
Table 6-4
EDID Commands
Command
Arguments
Description
DEL
ete
EDID
<list # | ALL>
Deletes the EDID information from the specified list
number.
Example:
To clear all EDID settings from the list,
type:
deledid all
DISPLAYMODE
<output # | ALL> [EMULATed
| PASSthrough]
Sets the display ID that is reported when the
EDIDMODE is set to DYNAMIC. EMULATED uses
the list entry specified with the
LoaDEmulateEDID
command. PASSthrough provides EDID from the
display connected to the specified output.
Example:
To set the display mode to PASSthrough
for output 4, type:
displaymode 4 pass
To display the current setting, do not enter a mode.
EDIDMODE
<input # | ALL>[FIXED |
DYNAMIC]
Sets the EDID mode for one or all inputs to
FIXED
or
DYNAMIC
. In
FIXED
mode, EDID parameters are
user defined regardless of output routing. In dynamic
mode, the EDID parameters may be emulated or
passed through from a connected output device.
Example:
To set the mode to DYNAMIC for all
inputs, type:
edidmode all dynamic
To display the current setting, do not enter a mode.
EDIDPR
iority
<input # | ALL>
[MINRES | output #]
When
EDIDMODE
is set to
DYNAMIC
, this
command chooses the EDID from the appropriate
output. When the priority is set to
MINRES
, the EDID
information is captured from the output, (source from
the selected input) with the lowest resolution. When
the priority is set to
OUTNUM
, EDID information is
obtained from the lowest number output to which the
selected input is routed.
Example:
To report EDID information from the
lowest resolution output for all inputs, type:
edidpri all minres
To display the current setting, enter the output
number or all only.