![RGB Spectrum Linx 1600 User Manual Download Page 23](http://html.mh-extra.com/html/rgb-spectrum/linx-1600/linx-1600_user-manual_1450537023.webp)
P H Y S I C A L D E S C R I P T I O N A N D I N S T A L L A T I O N
Linx 3200 (discontinued)
350-10035-01 v4.1.1
Linx DVI Matrix Switchers User’s Guide
11
RGB
2.2.2
Front Panel Description
See the
Linx 3200S
for a full discussion of front panel features.
A I R F I L T E R S
Six 4-40 x 1/4” Phillips flathead screws hold the air intake cover in place. Remove these
screws to access the foam air filter(s). The two power supplies are located behind the
foam filters.
See
Chapter 9
for instructions on cleaning and replacing the air filters.
Figure 2-3
Linx 3200 Front View
P O W E R S U P P L I E S
The two system power supplies are located behind the air intake upper foam filter. The
power supplies are redundant. One supply may be powered off and swapped while the
unit is powered on without interruption.
CAUTION
Do not operate the
Linx DVI Switcher
without the air filters in place. Doing so will
cause the unit to overheat.
link
activity
PRESS TO
SELECT
alarm
power A
power B
SPECTRUM
R
B
G
System IP Address
192.168.1.101
DST
PST
SYS
TAKE
SRC
Air Filter
LEDs
Display
Control Knob
Buttons