Radio Frequency Systems
BD210WLP Series Air Dryer User’s Guide
Page 26 of 101
100518832 – Rev. B
With Compressor NOT running:
6.5.21.1
Listen for any ‘hissing’ sounds which may indicate a fitting or hose
air leak.
With Compressor running:
6.5.21.2
Use a 1-inch paint
brush to dab soapy water
on the air fitting or hose
connection to be tested.
If air bubbles appear at the
connection, this indicates that
air is leaking from the
connection.
If any leaks are detected, take steps to seal them off (as necessary):
Tighten the fitting
Re-connect the hose end
Replace the fitting / hose / component
6.5.22
It is recommended to observe the air dryer for a minimum of 30 minutes
(1 hour preferred) and/or through multiple run and dwell cycles to ensure
there are no issues (e.g., humidity, flow, compressor run time, etc.) which
may result in alarms and/or dryer shut down.
6.5.23
Re-install the top panel and fasten the latches.
6.5.24
REGISTER YOUR DRYER. See section 7. for details.
Note:
Contact RFS technical support with any questions or concerns during
installation. See section 0