9.11.6
Press the
RESET
Button
to clear
the alarm.
If you are unable to create a High Outlet
Pressure Alarm as described, see section
13.7 for troubleshooting information.
9.12 Testing Low Outlet Pressure Alarm
9.12.1
Make a note of the current
Outlet Pressure (
OUTP
) reading.
9.12.2
Loosen the retaining nut on the Outlet Pressure Regulator.
9.12.3
Turn knob
counterclockwise until
Outlet Pressure (
OUTP
)
reading drops below the
low outlet pressure
threshold (0.3 PSI, 2.1
KPa default). After one
(1) minute, the Low-
Pressure Alarm should appear on the display.