Radio Frequency Systems
BD210WLP Series Air Dryer User’s Guide
Page 93 of 101
100518832 – Rev. B
Re-measure
Compressor AMP
Draw
(section 9.2 )
Control Valve looking
for restrictions or kinks
Compressor failing
Remove Discharge
Hose from compressor
(hose to the heatless
Dryer)
Re-measure
Compressor AMP
Draw
(section 9.2 )
If measurement is still
above the
recommended amps,
replace the compressor
(section 11.1)
or send it in for repair
(section 12. )
13.18 High Compressor Last Run Time Alarm
Possible Cause
Check
Corrective Action
Low System Pressure
Verify System Pressure
(section 8.9 )
Adjust System Pressure
to 50 PSI (344.7 KPa) ±
2 PSI (13.8 KPa).
(section 8.9 )
Leak in air system
Check all hoses and
fittings between
compressor and Air
Tank for air leaks
(section 9.13 )
Connect, tighten, or
replace leaking
component
High Downstream
Flow condition
Verify outlet flow from
dryer is within unit
specifications
Reduce dryer outlet
flow requirement or set
Compressor Last Run
Time alarm threshold
accordingly
Defective control board Check that the
compressor cuts out
when the tank reading
reaches 50 PSI (344.7
KPa)
(section 9.3 )
Replace Control Board
(section 11.1 )
13.19 Can’t Create a High Compressor Last Run Time Alarm
Possible Cause
Check
Corrective Action
Summary of Contents for BD210WLP Series
Page 2: ......