Check for loose wiring. Refer to the Wiring Diagram (section 14.2 )
Replace defective fan (see sections 11.1 for part detail and 0for ordering
information).
Replace defective control board if fan does not respond properly to
temperature changes (see sections 11.1 for part detail and 0for ordering
information).
9.8 Testing Compressor ON/OFF Cycling
9.8.1
When the Unit Screen (8.5.5.1 ) displays TANK press the
HOLD Button
on the Front Panel to freeze that screen.
With Compressor running:
9.8.2
Verify the compressor shuts down when the tank pressure (
TANK
) reaches
50 PSI
(
344.7 KPa)
.
If the tank pressure (TANK) fails to reach 50 PSI (344.7 KPa), see section 13.16
for troubleshooting information.
With Compressor NOT running:
CAUTION
: Be careful when removing Air hose. System is pressurized.