Radio Frequency Systems
BD210WLP Series Air Dryer User’s Guide
Page 33 of 101
100518832 – Rev. B
8.5.5.1
Outlet Screen
OUTLET
– Outlet Pressure regulated by the Outlet Pressure Regulator
TANK
–Tank pressure- operates between 20 – 50 PSI (137.9 – 344.7
KPa).
HUMIDITY
– Humidity level of the system.
8.5.5.2
Compressor Run Time
LAST
– How many minutes the compressor ran during the last Air Tank
pressurization cycle.
TOTAL
– Number of hours of compressor run time since the total run
time value was manually reset
8.5.5.3
System Status
SYS STATUS
– Signal to determine if the unit is online or in shutdown
- Running Status of the system:
ONLINE
– System is online.
SHUTDOWN
– System has been shut down as a result of either a
humidity or high cabinet temperature alarm.
CAB TEMP –
Temperature of the dryer cabinet compartment
DUTY CYCLE
– Compressor run time as a percentage of total cycle time