With Compressor running:
9.13.2
Use a 1-inch paint brush to
dab soapy water on the air
fitting or hose connection to
be tested.
If air bubbles appear at the
connection, this indicates that
air is leaking from the
connection.
If any leaks are detected, take steps to seal them off (as necessary):
Tighten the fitting
Re-connect the hose end
Replace the fitting / hose / component