Radio Frequency Systems
BD210WLP Series Air Dryer User’s Guide
Page 11 of 101
100518832 – Rev. B
5.5 Dryer Function Overview
#
Component
Description
1
Inlet Muffler
Minimizes compressor intake noise
2
Compressor
Compresses air drawn in by the inlet muffler
3
Coalescing Filter
Removes liquid water droplets from the
airstream prior to the heatless dryer
4
Purge Outlet
Outputs heatless dryer purge air and the liquid
water from the coalescing filter
5
Heatless Dryer
Removes moisture from the compressed air.
6
Capacity Control Valve
Regulates system pressure and prevents air from
bleeding back through the heatless dryer.
7
Air Tank
Stores compressed dry air.
8
Outlet Pressure Regulator
Regulates the outlet pressure to the desired
outlet condition.
9
Humidity Sensor
Measures the humidity of the compressed air.
10 System Outlet
Outputs the tank air at the pressure set by the
outlet pressure regulator
11 Tank Pressure Transducer
Interprets tank pressure for display
12 Outlet Pressure Transducer Interprets outlet pressure for display