MANUAL

HUMIDIFIER CONTROL

24 VAC

SOLENOID VALVE

LEADS

HUMIDIFIER

24 VAC TERMINALS

ON FURNACE

NOTE: 

CONNECT SOLENOID 

VALVE TO HOT WATER IF 

HUMIDIFIER WILL BE 

OPERATED INDEPENDENT 

OF HEATING CALLS.

HUMIDIFIER

TRANSFORMER

(FIELD SUPPLIED)

120 VAC

24 VAC

24 VAC

SOLENOID VALVE

LEADS

120 VAC “EAC”

TERMINALS

ON FURNACE

MANUAL

HUMIDIFIER CONTROL

(R) 24 VAC

HOT TERMINAL

WARNING: DO NOT CONNECT FURNACE HUM TERMINAL

DIRECTLY TO HUMIDITY SENSING THERMOSTAT  HUM TERMINAL

INDOOR

EQUIPMENT

(HUM) 

TERMINAL

HUMIDIFIER

HUMIDITY SENSING

THERMOSTAT

24 VAC

SOLENOID VALVE

LEADS

EQUIPMENT

CONTROLLER

HUMIDIFIER

INDOOR

UNIT

24 VAC

SOLENOID

VALVE

LEADS

HUMIDIFIER

INDOOR

UNIT

24 VAC

SOLENOID

VALVE

LEADS

READ COMPLETE SAFETY INSTRUCTIONS AND INSTALLATION TEMPLATE BEFORE STARTING

This product must be installed by a qualified heating and air conditioning contractor. Failure to do so could result in serious injury from electrical shock. 

This product must be installed in compliance with all local, state and federal codes.

ATTENTION INSTALLER:

SBP SMALL BYPASS HUMIDIFIER

The humidifier can be installed on 

either the supply or return plenum 

of a forced air handling system and 

is easily reversible for installation 

with right hand or left hand bypass 

duct connections. The humidifier 

dimensions and serviceability must 

be considered when selecting the 

best location for the humidifier.

RETURN

RETURN

RETURN

SUPPLY

SUPPLY

SUPPLY

RETURN

RETURN

RETURN

SUPPLY

SUPPLY

SUPPLY

Horizontal

Upflow

90-1115

90-1116

90-1117

90-1118

90-1119

90-1079

WARNING

1. 

 ELECTRICAL SHOCK HAZARD.

 

Disconnect electrical power to the 

furnace and install lock-out tag 

before starting installation. Failure to 

do so could result in serious injury 

from electrical shock.

2. 

 SHARP EDGES HAZARD.

 Sharp 

edges may cause serious injury from 

cuts. Use care when making plenum 

openings and handling ductwork.

3. 

 RISK OF SCALDING.

 Water 

temperature over 125°F can cause 

severe burns and scald instantly. 

Shut off the hot water supply before 

disconnecting or tapping into any hot 

water supply line.

SPECIFICATIONS

HUMIDIFIER DIMENSIONS

Width 

(including solenoid valve):

 15

5

8

” 

Height 

(including drain spud):

 13” 

Depth

:

 10

1

4

BYPASS DUCT OPENING

6” diameter

PLENUM OPENING

9

1

2

”W x 9

1

2

”H

WATER FEED RATE

3 gph

ELECTRICAL DATA

24 VAC-60 Hz, 0.5 AMP 

CAUTION

1.  Do not install humidifier where freezing temperatures 

could occur. The water line could freeze and crack 

causing water damage to the home.

2.  Do not install humidifier or bypass connection on the 

furnace cabinet.

3.  Do not install humidifier or bypass connection on a 

plenum face where the blanked off ends of the cooling 

coil will restrict air movement through the humidifier.

4.  Do not set humidity level above recommended or to 

recommended level if condensation exists on inside 

windows of any unheated space, as condensation 

damage may result. Excess humidity can cause 

moisture accumulation which can allow the possibility 

for mold growth in the home.

5.  Do not connect humidifier transformer to 

blower motor wiring. Premature component 

failure may result.

6.  When installing Humidifier Control on downflow 

furnace, ensure blower continues to run 

after a heat call is satisfied to eliminate high 

temperatures from damaging the Control.

7.  Do not install humidifier where water pressure 

exceeds 125 psi, since damage to the 

humidifier may result. Follow codes in effect 

concerning pressure reduction.

8.  Do not install humidifier on systems with 

greater than 0.4 in. wg pressure differential 

between supply and return plenums.

RISK OF PROPERTY AND EQUIPMENT DAMAGE.

INSTALLATION OPTIONS

WIRING DIAGRAMS

HumidiTrac

  

Automatic Humidifier Control

For detailed Automatic Humidifier Control 

installation and wiring instructions,  

see Form IM-AHC-03 included with Control.

DIAGRAM A

FOR OPERATION DURING “HEAT CALL” ONLY

DIAGRAM B

FOR OPERATION WHEN BLOWER IS ENERGIZED

DIAGRAM D

ZONING HOOK-UP  

WITH EQUIPMENT CONTROLLER

DIAGRAM E

NEW COMMUNICATING CONTROL HOOK-UP  

WITH ALL INDOOR EQUIPMENT

DIAGRAM C

FOR HUMIDIFIER OPERATION WITH HUMIDITY SENSING 

THERMOSTAT

TEMPLATE MUST BE LEVEL

© 2018 CAC/BDP