Rexroth IndraDyn A
Application Notes
9-7
Notes:
•
A side:
The degree of protection on the flange side of
motors with a shaft seal is IP 65. However, the seal is
ensured only in case of splashing water. Liquid levels
present on the shaft end require a higher degree of
protection.
•
B side:
The degree of protection for the blower screens in
axial blowers is IP 24. Chips or larger dirt particles can
penetrate the blower screen as well.
•
Protection class:
The factory-attached protection class of
IndraDyn A motors must not be reduced by modifications
or by retrofitting accessories.
⇒
Already take the installation position and the protection class of the
motors into account when planning the system.
9.7 Housing
Paint
The paint use of the motor housing consists of a black (RAL9005) 2K-
Epoxydharz coating based on Epoxyd-Polyamid-Resin in water.
Chemically resistant against
Limited resistant against
Impermanent against
attenuated acids/brines
organic solvents
concentrated acids/brines
Water, sea-water, sewage
hydraulic oil
common machine oils
Fig. 9-11:
Varnish-resistance
The housing may be repainted, but the coat thickness may be no
more than 40 µm. Check the adhesion and resistance of the new paint
before painting.
Summary of Contents for IndraDyn A Series
Page 8: ...VI Table of Contents Rexroth IndraDyn A...
Page 12: ...1 4 Introduction to the Product Rexroth IndraDyn A...
Page 26: ...3 12 Safety Instructions for Electric Drives and Controls Rexroth IndraDyn A Notes...
Page 102: ...4 76 Technical Data Rexroth IndraDyn A...
Page 140: ...6 20 Type Codes Rexroth IndraDyn A...
Page 144: ...7 4 Accessories Rexroth IndraDyn A...
Page 194: ...9 38 Application Notes Rexroth IndraDyn A...
Page 198: ...10 4 Handling and Transportation Rexroth IndraDyn A...
Page 219: ......