8-2
Connection Techniques
Rexroth IndraDyn A
8.2 Power
Connection
The connection of power to IndraDyn A motors is made at the top of the
motors and can be established performed via a
flange socket or a
terminal box
.
B-side
right
left
A-side
top
bottom
mounting feet
(only in mounting style B35)
Lage_Leistungsanschluss_EN.EPS
Fig. 8-1:
Position of the power connection
Note:
•
When choosing the connection option “flange socket”,
please note that the power cable must be equipped with a
plug with a bayonet connection
.
•
When choosing the connection option “terminal box”,
please note that the power cable must be terminated with
ferrules on conductors U, V and W, and the PE (ground)
conductor must be equipped with a ring terminal.
•
The design of the power cable also depends on the drive
device used. Please observe the documentation of the
drive device.
Overview
Terminal box
Motor frame size
MAD/MAF
Flange socket
U-V-W
Max. cross section of
power cable
∅
PE
Connection thread
100
INS480
Ferrules
10mm²
M6
see motor dimension
sheet
130
INS380
Ferrules
25mm²
M8
see motor dimension
sheet
160
INS380
Ferrules
35mm²
M8
see motor dimension
sheet
180
not available
Ring terminal
50mm²
M12
see motor dimension
sheet
Fig. 8-2:
Overview power connection
Summary of Contents for IndraDyn A Series
Page 8: ...VI Table of Contents Rexroth IndraDyn A...
Page 12: ...1 4 Introduction to the Product Rexroth IndraDyn A...
Page 26: ...3 12 Safety Instructions for Electric Drives and Controls Rexroth IndraDyn A Notes...
Page 102: ...4 76 Technical Data Rexroth IndraDyn A...
Page 140: ...6 20 Type Codes Rexroth IndraDyn A...
Page 144: ...7 4 Accessories Rexroth IndraDyn A...
Page 194: ...9 38 Application Notes Rexroth IndraDyn A...
Page 198: ...10 4 Handling and Transportation Rexroth IndraDyn A...
Page 219: ......