8-10
Connection Techniques
Rexroth IndraDyn A
8.9 Holding
Brake
The motor holding brake is triggered either directly through the drive
device or externally.
Note:
•
For the connection layout, refer to Figs. 8-3 and 8-5 at the
beginning of this chapter.
•
Control voltage is +24 V
DC
(+/-10%)
•
Take note of the functional differences of an electrically-
clamping vs. an electrically-releasing brake (see Chapter
9.10 “Motor Holding Brake”).
8.10 Motor Cooling
Blower Connection
The motor blower is connected to the power supply system via a cable
and motor-protecting switch, and it functions independent of the drive
device.
PE
0,75 1,5 mm2
0,75 1,5 mm2
L2
L1
I>>
I>>
I>>
0,75 1,5 mm2
L3
1
2
3
M
3
Netzanschluß
mains connection
Ø 6...10 mm
Schutzschalter
protective switch
Steckverbinder
plug-in connector
INS0705
Lüfter
blower
4
INS0705
Blower_Connect.EPS
Fig. 8-15:
Blower connection diagram
Note:
•
To establish the connection, the blower plug must be
opened and closed.
•
The electric connection may only be established by skilled
personnel. Please observe the safety notes.
•
The seal of the plug housing may not be compromis.
•
The machine manufacturer selects the motor protecting
switch and the electrical protection. Please observe the
regulations in the country of installation.
Summary of Contents for IndraDyn A Series
Page 8: ...VI Table of Contents Rexroth IndraDyn A...
Page 12: ...1 4 Introduction to the Product Rexroth IndraDyn A...
Page 26: ...3 12 Safety Instructions for Electric Drives and Controls Rexroth IndraDyn A Notes...
Page 102: ...4 76 Technical Data Rexroth IndraDyn A...
Page 140: ...6 20 Type Codes Rexroth IndraDyn A...
Page 144: ...7 4 Accessories Rexroth IndraDyn A...
Page 194: ...9 38 Application Notes Rexroth IndraDyn A...
Page 198: ...10 4 Handling and Transportation Rexroth IndraDyn A...
Page 219: ......