8-4
Connection Techniques
Rexroth IndraDyn A
8.4
Power Connection via Terminal Box
Antriebs-
regelgerät
drive controller
M
3
Bremse/
brake
(optional)
U
1
2
3
GN/YE
U1
V1
W1
4
3
2
1
PTC
Klemmbrett
terminal block
PTC
Klemmleiste
terminal strip
1
6
5
3
2
7
8
5
6
MAx_Power_Connect2.EPS
(1):
Electrically-conducting connection to the motor housing
(2):
The shield connection must be properly made in the cable via the
cable grip after the cable grip is threaded into the terminal box
(3):
Only one PTC sensor is monitored. Connect the spare sensor only if
necessary, e.g. because of failure of the first sensor.
Fig. 8-5:
Layout of power connection in terminal box
Terminal box
IndraDyn A motors designed for drive combinations with higher DC bus
voltages - up to 750V
DC
– are equipped with
a terminal strip or terminal
block
in the terminal box for the connection of cables with ferrules.
1
2
4
6
5
3
4 x
MAx_Power_Box.EPS
(1):
Cover
(2):
Seal (gasket)
(3):
PE (ground) connection
(4):
Cable entry
(5):
U-V-W power connection
(6):
Terminal strip
Fig. 8-6:
Terminal box
Summary of Contents for IndraDyn A Series
Page 8: ...VI Table of Contents Rexroth IndraDyn A...
Page 12: ...1 4 Introduction to the Product Rexroth IndraDyn A...
Page 26: ...3 12 Safety Instructions for Electric Drives and Controls Rexroth IndraDyn A Notes...
Page 102: ...4 76 Technical Data Rexroth IndraDyn A...
Page 140: ...6 20 Type Codes Rexroth IndraDyn A...
Page 144: ...7 4 Accessories Rexroth IndraDyn A...
Page 194: ...9 38 Application Notes Rexroth IndraDyn A...
Page 198: ...10 4 Handling and Transportation Rexroth IndraDyn A...
Page 219: ......