Design and Installation Position
IndraDyn A motors can be delivered in designs B05 and B35. Please refer
to the table below for the conditions of installation permissible according
to EN 60034-7.
Permissible conditions of installation
Motor
design
Description
Sketch
Setup
IM B5
Flange mounting on
the drive end of the
flange
IM V1
Flange mounting on
the drive end of the
flange; drive side
pointing down
B05
IM V3
Flange mounting on
the drive end of the
flange; drive side
pointing up
IM B3
Base (foot) mounting,
feet at the bottom
B35
IM B5
Flange mounting on
the drive end of the
flange
Fig. 9-7:
Installation positions
IndraDyn A motors with a B35 design can be mounted by using the foot-
assembly or the flange-assembly method.
2
1
MAFMount2.EPS
(1):
Mounting feet
(2):
Flange for flange assembly
Fig. 9-8:
Methods of mounting the IndraDyn A
In the case of foot mounting, the forces of the load may only act in the
vertical direction perpendicular to and towards the plain of feet (
±
15°).
The transfer of forces with other effective force directions is not permitted.
Summary of Contents for IndraDyn A Series
Page 8: ...VI Table of Contents Rexroth IndraDyn A...
Page 12: ...1 4 Introduction to the Product Rexroth IndraDyn A...
Page 26: ...3 12 Safety Instructions for Electric Drives and Controls Rexroth IndraDyn A Notes...
Page 102: ...4 76 Technical Data Rexroth IndraDyn A...
Page 140: ...6 20 Type Codes Rexroth IndraDyn A...
Page 144: ...7 4 Accessories Rexroth IndraDyn A...
Page 194: ...9 38 Application Notes Rexroth IndraDyn A...
Page 198: ...10 4 Handling and Transportation Rexroth IndraDyn A...
Page 219: ......