9-6
Application Notes
Rexroth IndraDyn A
+-
15°
F
1
+-
15°
F
1
+-
15°
F
1
+-
15°
F
1
F
F
F
F
F
F
F
+-
15°
+-
15°
MAFMount.EPS
(1):
Mounting feet
Fig. 9-9:
Acceptable foot-mounting layouts
Notes:
•
Forces transferred from a gearbox must not act on the feet
of the motor; they must be supported by the gearbox itself.
•
An improper installation situation results in forces that can
quickly lead to motor damage.
•
Consider the alternative "flange mounting".
Vertical Assembly
In the case of vertical installation positions as shown in the figure below,
dirt and fluids can more easily enter the motor interior and cause
malfunctions or break downs.
IM V3
IM V6
1
1
MAFMount3.EPS
(1):
Shaft duct IP 40 (standard)
Shaft duct with radial shaft seal IP 65 (option)
Fig. 9-10: Motor installed vertically