Page 1: ...somfy com Dexxo Pro 800 1000 RTS 5048550F FR Manuel d installation DE Gebrauchsanweisung EN Installation manual PL Instrukcja montażu IT Manuale d installazione NL Installatiegids ...

Page 2: ...operation in Total opening mode 5 OPERATING TEST 5 Using the remote controls 5 Obstacle detection function 5 Built in lighting operation 5 CONNECTING PERIPHERALS 6 Description of the various peripherals 6 Electrical connections for the various peripherals 6 SETUP 7 General setup diagram 7 Meanings of the various parameters 7 CLEARING REMOTE CONTROLS AND ALL SETTINGS 9 Clearing remote controls 9 Re...

Page 3: ...ng with compliance with the above standards Failure to comply with these instructions absolves Somfy from any liability resulting from damage that may be caused Dexxo Pro is a product that must be installed inside the garage with an integrated back up control system Somfy hereby declares that the device is compliant with the essential demands and other relevant requirements of directive 1999 5 CE ...

Page 4: ...y be dangerous The structure of your garage walls lintel inside surfaces cross members door rails are used to mount the Dexxo Pro system Reinforce them where necessary Never splash water onto the system Never install Dexxo Pro in a location where water may cause damage The bottom edge of the door should be fitted with a rubber strip to avoid hard contact and enhance the contact surface If the gara...

Page 5: ...ounting screw all the way down Excessive tightening can damage the screw and cause the travel stop not to remain in place Fitting the chain retainer pads Fig 13 For chain rails only These pads are used to limit spurious noise linked to chain friction within the rail Position each of the pads in the first hole in the rail after the travel stop Make sure that the pad is pressed in all the way so tha...

Page 6: ...s C1 Memorising the remote controls for operation in Total opening mode Fig 17 Up to 32 control channels can be stored Running this procedure for a previously stored channel will clear it At this stage in the installation process the Dexxo Pro motor drive unit is ready to run PROGRAMMING Press for 2 s memorise remote controls Press for 7 s delete remote controls Modifying a setting value Using the...

Page 7: ...eration every time the door moves If the test fails no door movement is possible Sensor bar Fig 24 With self test program the setting P2 1 This is used to perform an automatic test of sensor bar operation every time the door moves If the test result is negative no door movement is possible Make sure you have correctly configured parameter P2 taking into account the photoelectric cells or the senso...

Page 8: ...lf test is run at the start of every operating cycle If value 2 is selected the safety system runs without a self test it is essential to test its proper operation every six months P3 Obstacle detection sensitivity 0 low sensitivity 1 low sensitivity 2 standard 3 high sensitivity If this setting is changed it is essential to run the force measurement sequence at the end of the installation procedu...

Page 9: ...nput will inhibit door opening A1 Safety action during closure 1 stop 2 stop partial re opening 3 fully reopen Value 1 is not allowed when using a sensor bar on the safety input A2 Obstacle detection action during closure 2 stop partial re opening 3 fully reopen t0 Total operating mode automatic timed close 0 to 12 time delay value value x 10 s 2 20 s t1 Lighting time delay 0 to 60 time delay valu...

Page 10: ... display is maintained as long as the pedestrian door contact remains open Ca Safety mechanism self test Displayed during safety mechanism self tests Cb Permanent hardwired control Indicates that the permanent hardwired control input is activated contact closed Commands from radio remote control units are inhibited Cd Working from back up battery Waiting for a command Programming codes displayed C...

Page 11: ...upport H1 Detection of forced entry Displayed when an action occurs from outside the garage read by reinjection of power Press a button on the memorised remote control to stop the siren Start a complete opening and closing cycle H2 Detection of forced entry Displayed when an action occurs from outside the garage read by optical encoder Press a button on the memorised remote control to stop the sir...

Page 12: ... Autonomy Yes battery pack compatible Réf 9001001 24 hours 5 to 10 cycles depending on door Charge time 48 hours OPERATION Forced operation mode By pressing and holding the motor control button Independent lighting control Yes for remote lighting Lighting time delay after movement Programmable 60 s to 600 s Automatic closing mode Yes programmable closing time delay from 10 to 120 s Orange light pr...

Page 13: ...45 475 0922 Jordan Somfy Jordan 962 6 5821615 Kingdom of Saudi Arabia Somfy Saoudi Riyadh 966 1 47 23 203 Jeddah 966 2 69 83 353 Kuwait Somfy Kuwait 00965 4348906 Lebanon Somfy Middle East 961 0 1 391 224 Malaisia Somfy Malaisia 60 0 3 228 74743 Mexico Somfy Mexico SA de CV 52 0 55 5576 3421 Morocco Somfy Maroc 212 22951153 Netherlands Somfy BV 31 0 23 55 44 900 Norway Somfy Norway 47 67 97 85 05 ...