background image

9

EN

REFITTING COVERS 

(Fig. 41)

Position the aerial and fit the covers.

 

To ensure proper remote control range, the aerial must be fitted in one of the two positions shown in Figure 41.

Used to lock the programming settings (end limit setting, self-learning, setup).

Simultaneously press the “

SET

”, “

+

” and “

-

” buttons:

- start by pressing “

SET

”.

- pressing “

+

” and “

-

” must take place within two seconds.

To access programming mode once again, repeat the same procedure.

Clearing remote controls 

Fig. 38

Press the “

PROG

” button until the light blinks (7 s).

This clears all of the remote controls memorised.

Resetting all settings 

Fig. 39

Press the “

SET

” button until the light goes out (7 s).

This clears all previously stored settings and returns them to their default values.

LOCKING PROGRAMMING 

(Fig. 40)

TROUBLESHOOTING

Operating codes displayed

Code

Description

Comments

C1

Waiting for a command

C2

Door opening

C3

Waiting for the door to close

C4

Door closing

C5

Obstacle detection

Displayed during obstacle detection then for 30 s.

C6

Safety input active

Displayed after a movement request or during movement, when the safety input is active.

This display is maintained as long as the safety input is active.

C9

Pedestrian door safety contact active

Displayed after a movement request or during movement, when the pedestrian door contact is open.

The display is maintained as long as the pedestrian door contact remains open.

Ca

Safety mechanism self test

Displayed during safety mechanism self tests.

Cb

Permanent hardwired control

Indicates that the permanent hardwired control input is activated (contact closed). Commands from radio 

remote control units are inhibited.

Cd

Working from back-up battery

Waiting for a command

Programming codes displayed

Code

Description

Comments

S1

Awaiting setting

Pressing the “

SET

” button for 2 s starts the learning mode.

S2

Learning mode

Pressing the “

OK

” button starts the learning cycle: the S2 display blinks during the entire cycle.

Pressing the “

+

” or “

-

” buttons will control the motor in forced mode.

F0

Awaiting remote control memorisation for 

operation in total opening

Pressing a button on the remote control allocates this button to the motor total opening control.

Pressing “

PROG

” once more switches to “awaiting remote control memorisation for operation in partial opening: 

F1

“ mode.

F1

Awaiting remote control memorisation for 

operation in partial opening

Pressing a button on the remote control allocates this button to the motor partial opening control.

Pressing “

PROG

” once more switches to “awaiting remotely controlled lighting memorisation: 

F2

“ mode

F2

Awaiting remotely controlled lighting 

memorisation

Pressing a button on the remote control allocates this button to the remotely controlled lighting control.

Pressing “

PROG

” once more switches to “awaiting remote control memorisation for operation in total 

opening: 

F0

“ mode.

Summary of Contents for Dexxo Pro 1000 RTS

Page 1: ...somfy com Dexxo Pro 800 1000 RTS 5048550F FR Manuel d installation DE Gebrauchsanweisung EN Installation manual PL Instrukcja montażu IT Manuale d installazione NL Installatiegids ...

Page 2: ...operation in Total opening mode 5 OPERATING TEST 5 Using the remote controls 5 Obstacle detection function 5 Built in lighting operation 5 CONNECTING PERIPHERALS 6 Description of the various peripherals 6 Electrical connections for the various peripherals 6 SETUP 7 General setup diagram 7 Meanings of the various parameters 7 CLEARING REMOTE CONTROLS AND ALL SETTINGS 9 Clearing remote controls 9 Re...

Page 3: ...ng with compliance with the above standards Failure to comply with these instructions absolves Somfy from any liability resulting from damage that may be caused Dexxo Pro is a product that must be installed inside the garage with an integrated back up control system Somfy hereby declares that the device is compliant with the essential demands and other relevant requirements of directive 1999 5 CE ...

Page 4: ...y be dangerous The structure of your garage walls lintel inside surfaces cross members door rails are used to mount the Dexxo Pro system Reinforce them where necessary Never splash water onto the system Never install Dexxo Pro in a location where water may cause damage The bottom edge of the door should be fitted with a rubber strip to avoid hard contact and enhance the contact surface If the gara...

Page 5: ...ounting screw all the way down Excessive tightening can damage the screw and cause the travel stop not to remain in place Fitting the chain retainer pads Fig 13 For chain rails only These pads are used to limit spurious noise linked to chain friction within the rail Position each of the pads in the first hole in the rail after the travel stop Make sure that the pad is pressed in all the way so tha...

Page 6: ...s C1 Memorising the remote controls for operation in Total opening mode Fig 17 Up to 32 control channels can be stored Running this procedure for a previously stored channel will clear it At this stage in the installation process the Dexxo Pro motor drive unit is ready to run PROGRAMMING Press for 2 s memorise remote controls Press for 7 s delete remote controls Modifying a setting value Using the...

Page 7: ...eration every time the door moves If the test fails no door movement is possible Sensor bar Fig 24 With self test program the setting P2 1 This is used to perform an automatic test of sensor bar operation every time the door moves If the test result is negative no door movement is possible Make sure you have correctly configured parameter P2 taking into account the photoelectric cells or the senso...

Page 8: ...lf test is run at the start of every operating cycle If value 2 is selected the safety system runs without a self test it is essential to test its proper operation every six months P3 Obstacle detection sensitivity 0 low sensitivity 1 low sensitivity 2 standard 3 high sensitivity If this setting is changed it is essential to run the force measurement sequence at the end of the installation procedu...

Page 9: ...nput will inhibit door opening A1 Safety action during closure 1 stop 2 stop partial re opening 3 fully reopen Value 1 is not allowed when using a sensor bar on the safety input A2 Obstacle detection action during closure 2 stop partial re opening 3 fully reopen t0 Total operating mode automatic timed close 0 to 12 time delay value value x 10 s 2 20 s t1 Lighting time delay 0 to 60 time delay valu...

Page 10: ... display is maintained as long as the pedestrian door contact remains open Ca Safety mechanism self test Displayed during safety mechanism self tests Cb Permanent hardwired control Indicates that the permanent hardwired control input is activated contact closed Commands from radio remote control units are inhibited Cd Working from back up battery Waiting for a command Programming codes displayed C...

Page 11: ...upport H1 Detection of forced entry Displayed when an action occurs from outside the garage read by reinjection of power Press a button on the memorised remote control to stop the siren Start a complete opening and closing cycle H2 Detection of forced entry Displayed when an action occurs from outside the garage read by optical encoder Press a button on the memorised remote control to stop the sir...

Page 12: ... Autonomy Yes battery pack compatible Réf 9001001 24 hours 5 to 10 cycles depending on door Charge time 48 hours OPERATION Forced operation mode By pressing and holding the motor control button Independent lighting control Yes for remote lighting Lighting time delay after movement Programmable 60 s to 600 s Automatic closing mode Yes programmable closing time delay from 10 to 120 s Orange light pr...

Page 13: ...45 475 0922 Jordan Somfy Jordan 962 6 5821615 Kingdom of Saudi Arabia Somfy Saoudi Riyadh 966 1 47 23 203 Jeddah 966 2 69 83 353 Kuwait Somfy Kuwait 00965 4348906 Lebanon Somfy Middle East 961 0 1 391 224 Malaisia Somfy Malaisia 60 0 3 228 74743 Mexico Somfy Mexico SA de CV 52 0 55 5576 3421 Morocco Somfy Maroc 212 22951153 Netherlands Somfy BV 31 0 23 55 44 900 Norway Somfy Norway 47 67 97 85 05 ...

Reviews: