9
EN
REFITTING COVERS
(Fig. 41)
Position the aerial and fit the covers.
To ensure proper remote control range, the aerial must be fitted in one of the two positions shown in Figure 41.
Used to lock the programming settings (end limit setting, self-learning, setup).
Simultaneously press the “
SET
”, “
+
” and “
-
” buttons:
- start by pressing “
SET
”.
- pressing “
+
” and “
-
” must take place within two seconds.
To access programming mode once again, repeat the same procedure.
Clearing remote controls
Fig. 38
Press the “
PROG
” button until the light blinks (7 s).
This clears all of the remote controls memorised.
Resetting all settings
Fig. 39
Press the “
SET
” button until the light goes out (7 s).
This clears all previously stored settings and returns them to their default values.
LOCKING PROGRAMMING
(Fig. 40)
TROUBLESHOOTING
Operating codes displayed
Code
Description
Comments
C1
Waiting for a command
C2
Door opening
C3
Waiting for the door to close
C4
Door closing
C5
Obstacle detection
Displayed during obstacle detection then for 30 s.
C6
Safety input active
Displayed after a movement request or during movement, when the safety input is active.
This display is maintained as long as the safety input is active.
C9
Pedestrian door safety contact active
Displayed after a movement request or during movement, when the pedestrian door contact is open.
The display is maintained as long as the pedestrian door contact remains open.
Ca
Safety mechanism self test
Displayed during safety mechanism self tests.
Cb
Permanent hardwired control
Indicates that the permanent hardwired control input is activated (contact closed). Commands from radio
remote control units are inhibited.
Cd
Working from back-up battery
Waiting for a command
Programming codes displayed
Code
Description
Comments
S1
Awaiting setting
Pressing the “
SET
” button for 2 s starts the learning mode.
S2
Learning mode
Pressing the “
OK
” button starts the learning cycle: the S2 display blinks during the entire cycle.
Pressing the “
+
” or “
-
” buttons will control the motor in forced mode.
F0
Awaiting remote control memorisation for
operation in total opening
Pressing a button on the remote control allocates this button to the motor total opening control.
Pressing “
PROG
” once more switches to “awaiting remote control memorisation for operation in partial opening:
F1
“ mode.
F1
Awaiting remote control memorisation for
operation in partial opening
Pressing a button on the remote control allocates this button to the motor partial opening control.
Pressing “
PROG
” once more switches to “awaiting remotely controlled lighting memorisation:
F2
“ mode
F2
Awaiting remotely controlled lighting
memorisation
Pressing a button on the remote control allocates this button to the remotely controlled lighting control.
Pressing “
PROG
” once more switches to “awaiting remote control memorisation for operation in total
opening:
F0
“ mode.