SOMFY Dexxo Pro 1000 RTS Installation Manual Download Page 12

11

EN

TECHNICAL SPECIFICATIONS

Dexxo Pro 800 RTS

Dexxo Pro 1000 RTS

BASIC TECHNICAL CHARACTERISTICS

Mains supply

230 V - 50 Hz

Max. power consumption

Standby-Operation

5 W - 600  W (with 500 W remote lighting)

Traction force

Peak force

Starting force (1)

800 N

 

650 N

1000 N

 

800 N

Use 

Number of Opening/Closing cycles per day

20 cycles max. per day with a standard rail - 50 cycles max. per day with a high performance rail tested 

for 36,500 cycles with a standard rail  and 90,000 cycles with a high performance rail 

Max. speed

18 cm/s

Programming interface

7 buttons - 2 character LCD display

Operating temperature

- 20 ° C / + 60 ° C -  indoor dry  - IP 20

Travel end limits

Mechanical stopper at opening 

Memorized end limit position at closing

Electrical insulation

Class 2: double insulation 

Built in lighting

24 V / 21 W ; BA15s socket

Somfy radio frequency

RTS 433.42 MHz

Number of channels that can be memorised

32

CONNECTIONS

Safety input

Type

Compatibility

Dry contact: NC

Photoelectric TX/RX cells - Reflex cell - Sensor strip with dry contact output

Pedestrian door safety input

Dry contact: NC

Wired control input

Dry contact: NO

Remote lighting output

230 V - 500 W - class 2 

Orange light output

24 V - 15 W with built in flashing control

24 V controlled power supply output

Yes: for possible photoelectric TX/RX cell self-test

Safety input test output

Yes: for possible reflex cell or sensor strip self-test

Accessory power supply output

24 V - 500 mA max

Remote aerial input

Yes: RTS aerial compatible (Réf. 2400472)

Backup battery input

 

Autonomy

Yes: battery pack compatible (Réf. 9001001)

24 hours; 5 to 10 cycles depending on door

Charge time: 48 hours

OPERATION

Forced operation mode

By pressing and holding the motor control button

Independent lighting control

Yes for remote lighting

Lighting time delay (after movement)

Programmable : 60 s to 600 s

Automatic closing mode

Yes: programmable closing time delay from 10 to 120 s

Orange light pre-warning

Programmable: with or without prior warning (duration set to 2 s)

Safety input operation

While closing 

Before opening  

(Dangerous Movement Area Accessible 

to the Public)

Programmable: Stop - Partial re-opening - Full reopening 

Programmable: no effect or motion refused

Built-in obstacle detection

Adjustable sensitivity: 4 levels

Operation when an obstacle is detected

Programmable : partial re-opening or full reopening

Preset partial opening command

Yes can be selected: adjustable partial opening position

Progressive start up

Yes

Opening speed

Programmable from 3.5 cm/s to 18 cm/s: 10 possible values

Closing speed

Programmable from 3.5 cm/s to 18 cm/s: 10 possible values

Closure approach speed

Programmable: does not slow down, short slowdown zone (30 cm), 

 

long slowdown zone (50 cm)

Troubleshooting

Recording and accessing data: Cycle counter, cycle counter with obstacle detection, number of radio 

channels stored, history of the last ten defects recorded.

(1) Maximum load for motor to start and drive door for at least 5 cm (according to RAL-GZ definition).

Dimensions

171 min

63.6

140

125

Available travel: 2,555 / 3,155

 Overall length: 3,295 / 3,895

 Overall length: 3,153 / 3,753

65.5

224.4

224.4

Fixation: 2,982 / 3,582

Rail: 2,900 / 3,500

Rail : 2,900 / 3,500

33.5

130.9

404.2

404.2

106

313.6

254.1

139.5

164.4

150.1

112.2

Summary of Contents for Dexxo Pro 1000 RTS

Page 1: ...somfy com Dexxo Pro 800 1000 RTS 5048550F FR Manuel d installation DE Gebrauchsanweisung EN Installation manual PL Instrukcja montażu IT Manuale d installazione NL Installatiegids ...

Page 2: ...operation in Total opening mode 5 OPERATING TEST 5 Using the remote controls 5 Obstacle detection function 5 Built in lighting operation 5 CONNECTING PERIPHERALS 6 Description of the various peripherals 6 Electrical connections for the various peripherals 6 SETUP 7 General setup diagram 7 Meanings of the various parameters 7 CLEARING REMOTE CONTROLS AND ALL SETTINGS 9 Clearing remote controls 9 Re...

Page 3: ...ng with compliance with the above standards Failure to comply with these instructions absolves Somfy from any liability resulting from damage that may be caused Dexxo Pro is a product that must be installed inside the garage with an integrated back up control system Somfy hereby declares that the device is compliant with the essential demands and other relevant requirements of directive 1999 5 CE ...

Page 4: ...y be dangerous The structure of your garage walls lintel inside surfaces cross members door rails are used to mount the Dexxo Pro system Reinforce them where necessary Never splash water onto the system Never install Dexxo Pro in a location where water may cause damage The bottom edge of the door should be fitted with a rubber strip to avoid hard contact and enhance the contact surface If the gara...

Page 5: ...ounting screw all the way down Excessive tightening can damage the screw and cause the travel stop not to remain in place Fitting the chain retainer pads Fig 13 For chain rails only These pads are used to limit spurious noise linked to chain friction within the rail Position each of the pads in the first hole in the rail after the travel stop Make sure that the pad is pressed in all the way so tha...

Page 6: ...s C1 Memorising the remote controls for operation in Total opening mode Fig 17 Up to 32 control channels can be stored Running this procedure for a previously stored channel will clear it At this stage in the installation process the Dexxo Pro motor drive unit is ready to run PROGRAMMING Press for 2 s memorise remote controls Press for 7 s delete remote controls Modifying a setting value Using the...

Page 7: ...eration every time the door moves If the test fails no door movement is possible Sensor bar Fig 24 With self test program the setting P2 1 This is used to perform an automatic test of sensor bar operation every time the door moves If the test result is negative no door movement is possible Make sure you have correctly configured parameter P2 taking into account the photoelectric cells or the senso...

Page 8: ...lf test is run at the start of every operating cycle If value 2 is selected the safety system runs without a self test it is essential to test its proper operation every six months P3 Obstacle detection sensitivity 0 low sensitivity 1 low sensitivity 2 standard 3 high sensitivity If this setting is changed it is essential to run the force measurement sequence at the end of the installation procedu...

Page 9: ...nput will inhibit door opening A1 Safety action during closure 1 stop 2 stop partial re opening 3 fully reopen Value 1 is not allowed when using a sensor bar on the safety input A2 Obstacle detection action during closure 2 stop partial re opening 3 fully reopen t0 Total operating mode automatic timed close 0 to 12 time delay value value x 10 s 2 20 s t1 Lighting time delay 0 to 60 time delay valu...

Page 10: ... display is maintained as long as the pedestrian door contact remains open Ca Safety mechanism self test Displayed during safety mechanism self tests Cb Permanent hardwired control Indicates that the permanent hardwired control input is activated contact closed Commands from radio remote control units are inhibited Cd Working from back up battery Waiting for a command Programming codes displayed C...

Page 11: ...upport H1 Detection of forced entry Displayed when an action occurs from outside the garage read by reinjection of power Press a button on the memorised remote control to stop the siren Start a complete opening and closing cycle H2 Detection of forced entry Displayed when an action occurs from outside the garage read by optical encoder Press a button on the memorised remote control to stop the sir...

Page 12: ... Autonomy Yes battery pack compatible Réf 9001001 24 hours 5 to 10 cycles depending on door Charge time 48 hours OPERATION Forced operation mode By pressing and holding the motor control button Independent lighting control Yes for remote lighting Lighting time delay after movement Programmable 60 s to 600 s Automatic closing mode Yes programmable closing time delay from 10 to 120 s Orange light pr...

Page 13: ...45 475 0922 Jordan Somfy Jordan 962 6 5821615 Kingdom of Saudi Arabia Somfy Saoudi Riyadh 966 1 47 23 203 Jeddah 966 2 69 83 353 Kuwait Somfy Kuwait 00965 4348906 Lebanon Somfy Middle East 961 0 1 391 224 Malaisia Somfy Malaisia 60 0 3 228 74743 Mexico Somfy Mexico SA de CV 52 0 55 5576 3421 Morocco Somfy Maroc 212 22951153 Netherlands Somfy BV 31 0 23 55 44 900 Norway Somfy Norway 47 67 97 85 05 ...

Reviews: