48 Hold-o-mat
®
– Operating instructions
Setting up
Customer service
instructions
Do not allow magnetic data carriers such as diskettes, credit cards,
cheque cards, ID cards with magnetic strips, magnetic tapes or watch-
es to come within 0.5 m of the unit.
Warning:
magnetic field
Customer service staff with active physical aids (such as heart pacema
kers) must observe a safety distance of at least 0.5 m from the unit.
The customer service operator must ensure that all other people with
active physical aids (such as heart pacemakers) observe a safety dis-
tance of at least 0.5 m from the unit.
Rehinging the door
The door can be easily rehinged within 10 to 15 minutes. Because the
unit casing has to be opened for this purpose, current-carrying parts
will be exposed. The door may only be rehinged by specialist personnel
(qualified electrician, service fitter, Hugentobler AG authorised sales
person), and only in accordance with the customer service instruction
provided for this purpose.
Withdraw the mains plug from the socket. Withdraw the plug from the
equipment socket of the unit controller. Store the power cable where it
is inaccessible to other persons for the duration of the customer service
work. Remove the two lower hinge screws and unhinge the door.
Remove the screw/s on the opposite side which hold/s the casing in
place at the bottom front (411: 2 additional screws under casing). At the
rear of the unit, remove the six/eight screws attaching the housing to
the rear wall.
Slide the casing towards the rear and at the front of the unit press the
main insulation slightly backwards in order to gain access to the two
earth plates on which the four magnets are located. Dismantle the two
earth plates and fit them on the opposite side. Slide the main insulation
forwards again and slide the casing into the front panel.
Securely tighten all six/eight screws on the rear panel. Securely tighten
the screw which holds the casing in position at the bottom front. Un-
screw the upper hinge pins and fit them on the opposite side. On the
side of the door on which the door hinge sleeves are fitted, remove the
cover caps located on the inside of the door. Remove the cover caps
on the narrow side of the door. Lever the door hinge sleeves out of the
holes using a suitable slotted screwdriver and fit them on the opposite
side.