SAFETY PRECAUTIONS
SeaBat 7125 ROV Operator‟s Manual
Page 7
May 30, 2011
Version 3
The following recommendations are made to protect the arrays while in use and in
storage.
For cleaning, use a mild, nonabrasive soap, fresh lukewarm water, and a soft
brush.
Rinse the sonar with fresh water after every use.
Do not clean the array or sonar by using hot or cold pressure washers. The
high-velocity water spray will cut through the polyurethane or damage the
interface between the polyurethane and the sonar metal housing.
Do not apply any antifouling paint on the acoustic window unless the type is
recommended by RESON. The antifouling paint will affect the acoustic
performance.
To scrape away marine growth from the arrays, use only a wooden tool.
2.2.2.2 7125 Processor Dust Filter
The 7125 processor is equipped with filters to prevent dust and other particles to enter
the unit. The dust filters need to be changed
at least
once a year:
Figure 3: 7125 Processor Filter Location
1. Unscrew the four corner screws.
2. Lift off the front panel.
3. Replace the three dust filters.
4. Reassemble the processor.