Rev. 1.00, 05/04, page 174 of 544
9.5.6
Timing of Input Capture Flag (ICF) Setting
The input capture flag, ICFA, ICFB, ICFC, or ICFD, is set to 1 by the input capture signal. The
FRC value is simultaneously transferred to the corresponding input capture register (ICRA, ICRB,
ICRC, or ICRD). Figure 9.11 shows the timing of setting the ICFA to ICFD flag.
Input capture
signal
φ
ICFA to ICFD
ICRA to ICRD
FRC
N
N
Figure 9.11 Timing of Input Capture Flag (ICFA, ICFB, ICFC, or ICFD) Setting
9.5.7
Timing of Output Compare Flag (OCF) setting
The output compare flag, OCFA or OCFB, is set to 1 by a compare-match signal generated when
the FRC value matches the OCRA or OCRB value. This compare-match signal is generated at the
last state in which the two values match, just before FRC increments to a new value. When the
FRC and OCRA or OCRB value match, the compare-match signal is not generated until the next
cycle of the clock source. Figure 9.12 shows the timing of setting the OCFA or OCFB flag.
Compare-match
signal
OCFA, OCFB
OCRA, OCRB
N
FRC
N
N + 1
φ
Figure 9.12 Timing of Output Compare Flag (OCFA or OCFB) Setting
Summary of Contents for H8S/2111B
Page 2: ...Rev 1 00 05 04 page ii of xxxiv...
Page 8: ...Rev 1 00 05 04 page viii of xxxiv...
Page 22: ...Rev 1 00 05 04 page xxii of xxxiv...
Page 30: ...Rev 1 00 05 04 page xxx of xxxiv...
Page 84: ...Rev 1 00 05 04 page 50 of 544...
Page 100: ...Rev 1 00 05 04 page 66 of 544...
Page 126: ...Rev 1 00 05 04 page 92 of 544...
Page 180: ...Rev 1 00 05 04 page 146 of 544...
Page 216: ...Rev 1 00 05 04 page 182 of 544...
Page 254: ...Rev 1 00 05 04 page 220 of 544...
Page 268: ...Rev 1 00 05 04 page 234 of 544...
Page 382: ...Rev 1 00 05 04 page 348 of 544...
Page 462: ...Rev 1 00 05 04 page 428 of 544...
Page 464: ...Rev 1 00 05 04 page 430 of 544...
Page 488: ...Rev 1 00 05 04 page 454 of 544...
Page 496: ...Rev 1 00 05 04 page 462 of 544...
Page 574: ...Rev 1 00 05 04 page 540 of 544...
Page 581: ......
Page 582: ...H8S 2111B Hardware Manual...