This dialog box allows the user to analyze statistical information concerning the trace information. Set the target
of analysis in [Item] and the input value or character string by [Start] and [End]. Click the [Result] button after
setting a condition by pressing the [New] or [Add] button to analyze the statistical information and display its
result in the [Result] list.
Note: In this emulator, only [PTR] can be set as a range. Each of other items must be specified as a character
string. In analysis of statistical information, character strings are compared with those displayed in the
[Trace] window. Only those that completely match are counted. Note, however, that this test is not case
sensitive. The number of blanks will not be cared either.
5.8.15
Extracting Function Calls from the Acquired Trace Information
To extract function calls from the acquired trace information, select [Function Call…] from the popup menu.
The [Function Call Display] dialog box will be displayed.
Figure 5.57 [Function Call Display] Dialog Box
[Setting]:
Selects whether or not to extract function calls.
[Enable]: Extracts
function
calls.
[Disable]:
Does not extract function calls.
When [Enable] is selected, only the cycles that include function calls are extracted for display from the acquired
trace information. The content of the trace buffer is not changed by extraction of function calls. Using this
function for the result of the free trace or the trace information that includes function calls allows the user to
know the order of function calls.
Summary of Contents for H8 Series
Page 4: ......
Page 6: ......
Page 20: ...viii...
Page 21: ...Emulator Debugger Part...
Page 22: ......
Page 26: ...4...
Page 40: ...18...
Page 46: ...24...
Page 148: ...126 Figure 6 8 Editor Window Break Status...
Page 202: ...180...
Page 250: ...228...
Page 262: ...240...
Page 271: ......