177
7.3
Differences between MCU and Emulator
When the emulator is turned on or initialized, or the system is reset, there are some differences in the initial
values in some of the general registers between the MCU and the emulator as shown in table 7.2.
Table 7.2
Initial Value Differences between MCU and Emulator
Status Register
E6000
Emulator
MCU
PC
Reset vector value
Reset vector value
ER0 to ER6
Undefined
Undefined
ER7 (SP)
H'10
Undefined
Power-on/
initialized
CCR
The I mask is set to 1 and the
other bits are undefined
The I mask is set to 1 and the
other bits are undefined
PC
Reset vector value
Reset vector value
ER0 to ER6
Undefined
Undefined
ER7 (SP)
H'10
Undefined
Reset command
CCR
The I mask is set to 1 and the
other bits are undefined
The I mask is set to 1 and the
other bits are undefined
7.3.1
A/D Converter and D/A Converter
Due to the use of a user system interface cable, there is a slight degradation in the A/D and D/A conversion than
that quoted in the Hardware Manual for the MCU being emulated.