171
(2) Set the items in the [Monitor Setting] dialog box as follows:
•
Enter monitor1 in the [Name] edit box.
•
Set the parameters in the [Options] group box as follows:
(a)
Use the [Locals] window to refer to the address on the line where variable
a
, which is defined within
the
tutorial
function, is allocated and enter this address in the [Address] edit box. In this example,
enter
H’00FFEF80
.
(b)
Enter
H’50
in the [Size] edit box.
(c)
Select BYTE (HEX) from the [Access] combo box.
(d)
Check the [Auto-refresh at rate] check box and enter
D’00500
.
(e)
Check the [Reading the Initial Value] check box.
•
Set the parameters in the [Color] group box as follows:
(a)
Select Change from the [Change Indicator] combo box.
(b)
Select red and white in the [Foreground] and [Background] combo boxes, respectively.
(c)
Check the [Mayfly] check box.
Note: Depending on the operating system in use, the foreground and background colors may not be selectable.