rev04
17
17. TROUBLESHOOTING GUIDE
Malfunction
Recommended inspections / operations
The alarm does not respond to the
transmitter.
- Make sure the system has not entered the sleep condition (see paragraph 14)
- Operate the transmitter closer to the unit (the area might be affected by noises interfering with the radio
signal)
- Replace the transmitter battery
- Realign the transmitters (see paragraph 16.1)
- If none of these operations is successful, contact your dealer (in the meantime, if the system is armed,
disarm it with the PIN code (see paragraph 15)
The system is not triggered by
moving/lifting
- Has the inhibition time elapsed?
- Is the movement detector activated (not deselected)?
- If necessary, please adjust the movement detector (see paragraph 11).
- If none of these operations is successful, contact your dealer
18. TECHNICAL DATA
Power supply (control unit)
Nom. 12 V Max 17 V Min. 9 V
Current consumption rate
< 1 mA OFF; 1 mA ON (including the LED)
Back-up battery
Rechargeable 7,2V 170 mAh NiMH battery
Operating temperature
-20 °C / +85 °C
Siren sound power
114 dB @ 1 m
Size of the control unit
90 x 67 x 30 mm
Size of the transmitter
50 x 37 x 12,5
Transmitter battery
3 V CR2032
Transmitter battery life
Min.12 months (with Main-libre function on)