C-11
Appendix C Subscriber Unit Event Log Messages
Redline Communications Inc. Confidential and Proprietary
Provision: reboot request
TFTP self-provisioning log
You need to correct and update the required
configuration file stored on the TFTP server.
You can manually configure the subscriber
through the sector controller or RMS.
Provision: updated
configuration
TFTP self-provisioning log
You need to correct and update the required
configuration file stored on the TFTP server.
You can manually configure the subscriber
through the sector controller or RMS.
Provision: upgrade image has
same version
TFTP self-provisioning log
You need to correct and update the required
configuration file stored on the TFTP server.
You can manually configure the subscriber
through the sector controller or RMS.
Pwr IE (nn) Current: nn.
Anomaly: Too High
Normal operation. There is no action required.
Pwr IE (nn) Current: nn.
Anomaly: Too Low
Normal operation. There is no action required.
Pwr IE (nn) Current: nn.
Success
Normal operation. There is no action required.
Rng Assigned Diuc nn.
These messages are part of the
ranging sequence. As the subscriber
progresses through the initial ranging
procedure, these messages may be
added to the event log.
Normal operation. There is no action required.
Ranging in progress cancelled
by watchdog
Debug message. The watchdog has
been triggered to avoid data traffic
loss due to range lock.
Information only. There is no action required.
During ranging, data traffic is temporarily halted
to facilitate the ranging operation. If for some
reason the ranging does not completed as
expected, then after a preset delay the watchdog
is triggered and it re-establishes data traffic.
Read BS Table ([nn] valid
entries)
The subscriber is trying to determine
the number of sector controllers were
listed at startup
Information only. There is no action required.
Remove SA ID [nn]
Security association ID deleted.
Information only. There is no action required.
When privacy is enabled, this is one of the many
steps that subscriber must perform to complete
the authentication process.
Reset Button Pressed
The reset button on the subscriber unit
has been activated.
Information only. There is no action required.
RF PLL Error
PLL in the RF module failed to lock
(hardware issue),
Contact [email protected].
Table C-1
Subscriber Event Log Messages (continued)
Message
Description
Analysis